EDX-1210/EDX-620 [EUM-D] 15
2-5 Zone Setting
Definition of zone: In EDX system, the device must set the zone number before using, which
consists of two parts, one is the zone number and another is the start channel.
For example: There are 4 EDX-1210 (48 channels in total) in zone 1, the zone number of each
device should be 01-01,01-13,01-25,01-37 respectively.
STEP-1: Press
【
FNC
】
to enter the menu. Select "
F3: ZONE SET "
, and LCD shows:
The two digit number, "01", is zone number. The three digit number, "001", is the starting channel.
STEP-2: Press
【
】
or
【
】
to select between zone and start channel. Press
【
】
or
【
】
to set
the number.
STEP-3: Press
【
ENTER
】
to save the setting or press
【
FNC
】
to exit.
2-6 Save Scenes
STEP-1: Set EDX-1210 the dimming levels by the dimming sliders. For example, set channel 1 to 4 as
100% and set channel 5 to 8 as 50%
;
Set EDX-620 the dimming levels by the dimming sliders. For
example, set channel 1 to 4 as 100% and set channel 5 to 6 as 50%
STEP-2: Press
【
】
or
【
】
to enter scene editing function.
The LCD shows the current dimming level for each channel as (EDX-1210)12 and (EDX-620) 6 bars.
STEP-3: To further adjust the dimming level, press
【
】
or
【
】
to select a channel, and press
【
】
or
【
】
to set the level of the channel.
STEP-4: Pres
【
ENTER
】
, LCD shows:
STEP-5: Press
【
】
or
【
】
to select a scene number to save the current dimming levels.
Содержание EDX-1210
Страница 1: ...EDX 1210 EDX 620 EUM D 1 User Manual EDX 1210 EDX 620 12 6 Channel Dimmer Pack...
Страница 7: ...EDX 1210 EDX 620 EUM D 7 1 5 Output Terminals EDX 1210 EDX 620 EDX 1210...
Страница 8: ...EDX 1210 EDX 620 EUM D 8 EDX 620...
Страница 9: ...EDX 1210 EDX 620 EUM D 9 1 6 Analog 0 10V DC Output Terminals EDX 1210 EDX 620 EDX 1210...
Страница 10: ...EDX 1210 EDX 620 EUM D 10 EDX 620...
Страница 11: ...EDX 1210 EDX 620 EUM D 11 1 7 Dimension...