4
ECP-A02T [EUM-A]
2. Operations
ECP-A02T controls EDX-A01D through DP-NEX1
Please set DMX-512 address and zone number on ECP-A02T before use.
More information please refer EDX-A01D user manual.
2-1 Zone Setting
Hold 【TEMP+】and 【TEMP-】at the same time, then press 【FAN+】or【FAN-】 to
set zone number from 001 – 099.
Figure: zone 01 – zone 99
-
2-2 DMX-512 Start Address Setting
Hold 【FAN+】and 【FAN-】at the same time, then press 【TEMP+】or【TEMP-】 to
set DMX-512 start address from 001 – 512.
Figure: DMX 001 – DMX 512
-
If you set DMX-512 start address as 1, then ECP-A02T will control 1
th
and 2
st
channel in
DMX-512.
Please set EDX-A01D (HVAC module) as the same address of ECP-A02T to make sure
that EDX-A01R will be controlled by ECP-A02T.
Example: If the DMX-512 start address of EDX-A01R is 9, please set the start address
of ECP-A02T to 9.