ISO 9001 CERTIFIED                                                                                  www.liteputer.com.tw

 

Lite-Puter 

ECP-110T[EUM-B] 

10 

2-6 Dry Contact Inputs 

The scene 1 will be recalled by actuating input 1. 

The scene 2 will be recalled by actuating input 2. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание ECP-110T

Страница 1: ...ISO 9001 CERTIFIED www liteputer com tw Lite Puter ECP 110T EUM B ECP 110T Control Panel USER MANUAL Lite Puter Enterprise Co Ltd Website www liteputer com tw E mail sales liteputer com tw...

Страница 2: ...4 HOW TO OPEN FRONT COVER 3 1 5 WIRING 3 2 OPERATIONS 4 2 1 ZONE SETTING 4 2 1 1 About EDX System 4 2 1 2 Purpose of Zone Setting 5 2 1 3 Zone Setting 5 2 1 4 Zone Setting of DIP 8 2 2 SCENE RECALL 8...

Страница 3: ...ol up to 8 zones at the same time 2 Recall 6 scenes 3 Fine adjust the dimming level 4 256 level dimming resolutions 5 Key Lock unlock function 6 IR receiver 7 Two dry contact inputs 1 2 Specifications...

Страница 4: ...ISO 9001 CERTIFIED www liteputer com tw Lite Puter ECP 110T EUM B 2 Rear side 1 Scene 1 6 scene OFF 2 Down Up 3 ZONE zone 4 DIP switch...

Страница 5: ...ISO 9001 CERTIFIED www liteputer com tw Lite Puter ECP 110T EUM B 3 1 4 How to Open Front Cover Slotted Screwdriver 1 5 Wiring...

Страница 6: ...al lighting applications EDX dimmers or devices are able to store scenes in themselves Each EDX device or ECP panel can be assigned a zone number The scenes stored in EDX devices can be recalled by EC...

Страница 7: ...OFF panel setting zone 2 1 3 DIP 10 ON DIP setting zone 2 1 4 ECP 110T has 2 control modes single zone mode or multi zone mode DIP 9 OFF single zone mode DIP 9 ON multi zone mode 2 1 3 Zone Setting 1...

Страница 8: ...tructions Single zone mode DIP9 OFF Each button presents 1 1 2 2 3 4 4 8 5 16 6 32 64 128 For example to set zone number as 3 in single zone mode Press 1 2 to make their backlight to red 1 1 2 2 1 2 3...

Страница 9: ...ne 1 2 zone 2 3 zone 3 4 zone 4 5 zone 5 6 zone 6 zone 7 zone 8 For example to set zone number to 1 and 2 to control zone 1 and 2 at the same time Press 1 and 2 to make their backlight to red For exam...

Страница 10: ...call Press 1 6 to recall corresponding scenes For example press 1 to recall the SC1 and the backlighting of the button will be in red Press 1 6 once the scenes will be recalled with fade in effect Qui...

Страница 11: ...lock Lock Unlock 2 5 IR Remote Control ECP 110T can receive infrared signal from remote controller IR 0501 to recall the scenes and adjust dimming level 1 Hold ZONE and then hold 2 for 5 seconds till...

Страница 12: ...ISO 9001 CERTIFIED www liteputer com tw Lite Puter ECP 110T EUM B 10 2 6 Dry Contact Inputs The scene 1 will be recalled by actuating input 1 The scene 2 will be recalled by actuating input 2...

Страница 13: ...000 18 01001000 19 11001000 20 00101000 21 10101000 22 01101000 23 11010000 24 00011000 25 10011000 26 01011000 27 11011000 28 00111000 29 10111000 30 01111000 31 11111000 32 00000100 33 10000100 34 0...

Страница 14: ...arranty does not cover a Any fault caused by false usage imprudence collision inadequate installation or adjustment insufficient ventilation or improper repairs b Force majeure factors flooding earthq...

Страница 15: ...No 189 Gangqian Rd Neihu Dist Taipei City 11494 Taiwan Tel 886 2 27998099 Fax 886 2 27993828 Website www liteputer com tw E mail sales liteputer com tw Shanghai Factory Lite Puter Technology Shanghai...