SAFETY INTRODUCTION
The Load Power
Please refer to the data we suggested to ensure the normal total working hours
of DX-610/DX-626
1.
If DX-610/DX-626 is installed in a rack, please make sure the rack is airy.
Otherwise the machine will become over-heat and result in the
mis-function.
2.
DX-610: the max. output of each channel is10A: For testing (DO Not over 30
minutes)
DX-626: the max. output of each channel is 20A: For testing (DO Not over
30 minutes)
3.
DX-610: the output of each channel is
Ŋ
8A: For several hours use (Theaters,
Stages)
DX-626: the output of each channel is
16A: For several hours use
(Theaters, Stages)
4.
DX-610: the output of each channel is
8A: Can work for the whole year
without switching off (Hotels, Restaurants, Buildings)
DX-626: the output of each channel is
12A: Can work for the whole year
without switching off (Hotels, Restaurants, Buildings)
Working Environment
1. Temperature
Under 35°C
2. If the machine is installed in a rack, then the temperature inside the rack
must be under 45°C
3. Humidity
40% --- 80%
Suggested Dimming Lights
Incandescent lamps, halogen lamps, low volt halogen lamps with ballast.