DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 17
4-5-4 Display Voltage Input
The function is to display AC voltage input.
.
.
4-5-5 Display Internal Temperature
.
.
When the internal temperature is over 34
°C
, the fans start to work 1 minute and stop 1 minute
in turn.
When the internal temperature is over 37
°C
, the fans turn on continuously.
When the internal temperature is over 63
°C
, all output will be stopped until the temperature is
under 60
°C
. In this case, please check whether the dimmer is overloaded.
4-6 SET Functions
Press
"SET"
key in turn and the LED will display 5 functions as follows:
1.
Dimmer warm-up 0% - 6.0%.
2.
Dimming or switch (non-dim) modes
3.
Fader time: 0.1 SEC - 30 MIN.
4.
Dimming curves.
5.
Maximum wattage limit setting
4-6-1 Dimmer Warm-up
.
.
.
Press
【
►
】
:
Increase channel.
Press
【
◄
】
:
Decrease channel.
Press
【
▲
】
:
Increase dimmer- warm up value.
Press
【
▼
】
:
Decrease dimmer- warm up value.
.
Press
【
CAN
】:
Return
Warm-up function of a channel will be invalid if the channel is set to switch mode (non-dim) .
All channels
Warm up level