25
alpha series lWa/lWX genset operators' handbook
6. duMMy load
The Dummy load comprises of a
number of resistive elements, to
suit the configuration of the genset,
mounted in front of the radiator and
a control system to turn the load on
and off. The control system is via the
control module fitted in the genset
control panel.
When the genset is started, the Control
module will monitor the load and control
when the dummy load is required. If the
load level is below the 'trip' setting for
the duration of the 'trip delay' (initially
set to 10 minutes) then the dummy load
control is activated.
If the load level rises above the 'return'
setting for the duration of the 'return
delay' (initially set to 1 second) then
the dummy load is deactivated and the
timer is reset.