Safety Considerations

SoundConnect has been designed and tested according to IEC Publication 348, Safety Requirements for 
Electronic Measuring Apparatus, and has been supplied in safe operating condition. This User’s Manual 
contains information and warnings that should be followed by the user to ensure safe and service free 
operation. Special note should be made of the following:

Application of Power

Before turning on SoundConnect, check that it is set to match the available mains voltage and that the 
correct fuse is installed.

Safety Symbols

z

The apparatus will be marked with this symbol when it is important that the user refer 

to associated warning statements given in the User’s Manual.

z

Hazardous voltage

Warnings

Whenever it is likely that the correct functioning or operating safety of the apparatus has been impaired, 
the apparatus must be made inoperative and be secured against unintended operation. 

Any adjustment, maintenance and repair of the open apparatus under power must be avoided as far as 
possible and, if unavoidable, must be carried out only by trained service personnel.

Rev 043015

     

!

     

Содержание SoundConnect

Страница 1: ...ectTM Microphone Power Supply Instruction Manual April 2015 2006 2015 Listen Inc Sound Measurements Make Sound Products 580 Harrison Ave Suite 3W Boston MA 02118 617 556 4104 Fax 617 556 4145 www list...

Страница 2: ...t to match the available mains voltage and that the correct fuse is installed Safety Symbols zThe apparatus will be marked with this symbol when it is important that the user refer to associated warni...

Страница 3: ...andling of the Products against defects or damages arising from improper installation where installation is by persons other than Manufacturer against defects in products or components not manufacture...

Страница 4: ...acquisition boards for converting the input signal into the digital domain Using SoundConnect s output attenuator and peak level meter it is easy to achieve the full performance from these boards Thr...

Страница 5: ...peak 5 VRMS A3 should be set to the closest setting which best matches the data acquisition board s maximum input voltage specification If the board s limit falls in between A3 s settings select the l...

Страница 6: ...oratory calibrate test instrumentation at least once a year Service and Repair SoundConnect is designed and constructed to provide the user with many years of safe and trouble free operation However s...

Страница 7: ...tput must be connected to the 3 pin header at the top of the frontend pc board 2 Slide the case off of the base plate 5 Replace the case by sliding it into the first groove on each side of the base pl...

Страница 8: ...Megohm z Output impedance 600 ohms z Output attenuator 0 dB 7 07 VP 8 dB 2 82 VP 14 dB 1 41 VP 0 1 dB z Peak Level Meter Indication at 20 10 0 dB and overload relative to selected output range 0 5 dB...