INSTALLATION
OVERVIEW
03
www.liquagen.com
www.liquagen.com
1/4” Red
Tubing
STAGE 1
Sediment filter
STAGE 2
UDF/GAC
STAGE 3
Carbon
STAGE 4
RO Membrane
1/4” White
Tubing
STAGE 5
DI Cartridge
STAGE 6
DI Cartridge
UNDERSTANDING
PERFORMANCE
12
MEMBRANE CAPACITY
PER DAY
PER HOUR
50 GPD
75 GPD
100 GPD
150 GPD
40 GPD
60 GPD
80 GPD
120 GPD
1.67 GPH
2.5 GPH
3.33 GPH
5 GPH
In our 25 years of research and customer feedback, we've found that the
majority of the membranes operate at 80% capacity regardless of the
brand.
GPD refers to gallons per day. Reverse Osmosis systems are rated in the
number of gallons they produce in 24 hours.
Only under perfect conditions does the membrane perform at full GPD
capacity. The performance depends on water quality, pressure, and
temperature.
For every gallon produced, the system will waste roughly 3 gallons of
water.
To maintain a 99% rejection rate, it is imperative that you disregard the
amount of wastewater. This is a standard industry norm regardless of the
brand. Wastewater can be reduced by adding an ERP pump or a water saver
kit while still maintaining a 98 to 99% rejection rate.