Flow Max

 12V DC 

Fluid Pump 

by Duraself

Installation and Owner’s Manual

(For Aftermarket Application)

Resources Required

• Cordless or Electric Drill or Screw Gun
• Appropriate Drive Bits
• Cutting Implement for Tubing 
• Flexible, Reinforced Hose with 

1/2

" Minimum Inner Diameter

• Appropriate Pipe Fittings as Needed
• Four Screws to Fasten Pump to Mounting Surface
• 

15 Amp Electrical Cutoff Switch

Mounting Instructions

1. 

Pump may be located at the same level or below the 

water tank. However, if necessary, the pump may be 

positioned above the water tank since it is capable of a 

6 ft. vertical prime. Also, horizontal inlet tubing will allow 

priming to 30 ft.

2. 

Consider a dry location that allows easy access, if 

maintenance is required.

3. 

Installation space for pump should be at least 1 

cubic feet to allow for adequate ventilation and prevent 

overheating.

NOTE: 

Excessive heat may trigger the integral thermal 

breaker and interrupt operation. When the temperature 

drops, the breaker will automatically reset.

4. 

Pump may be mounted in any position. However, if 

pump is mounted vertically, the pump head should be in 

the down position to avoid leakage into the motor casing 

during a malfunction.

Installation

The following guidelines should be considered to achieve 

optimum pump performance. Mount the pump with 4 

screws. In many instances, the pump is being utilized as a 

replacement pump. Adjust instructions as needed.

NOTE: 

The mounting feet are intended to isolate the pump 

from the mounting surface. Overtightening, flattening or 

use of oversized screws will reduce the ability to isolate 

vibration and noise through the lines.

NOTE: 

Always follow all local or national installation codes 

and standards.

General Installation Instructions

1. 

Solid surface should be available for mounting to prevent 

vibration and noise.

2. 

Accessible location away from living quarters.

3. 

Properly-sized wiring.

4. 

Proper electrical protection.

5. 

Flexible hose on inlet and outlet.

6. 

Strainer on plumbing elbows and valves near the pump.

7. 

Minimize flow restrictions in the system.

Содержание 689052

Страница 1: ...ion Table of Contents Introduction 2 Parts List 2 Resources Required 3 Installation 3 General Installation Instructions 3 Mounting Instructions 3 Plumbing The System 4 Electrical Connections 5 Sanitiz...

Страница 2: ...designed for intermittent duty only Do not use the pump for running a Reverse Osmosis RO Filtration System Continuous running under higher pressure may reduce pump life There are no replaceable parts...

Страница 3: ...mal breaker and interrupt operation When the temperature drops the breaker will automatically reset 4 Pump may be mounted in any position However if pump is mounted vertically the pump head should be...

Страница 4: ...ve fittings and connections e g elbows T s and feeder lines to faucets To reduce rapid cycling the pump shutoff pressure switch setting Fig 3 can be increased by turning the screw clockwise 1 1 2 turn...

Страница 5: ...eeded to sanitize the tank 2 Mix the bleach with water in a container 3 Pour the bleach solution into the tank and fill the tank with potable water 4 Open all faucets hot and cold and allow water to r...

Страница 6: ...water tank NOTE If the tank doesn t have a drain valve open all faucets while allowing the pump to operate 15 minutes on 15 minutes off until the tank is empty 2 Open all the faucets including the low...

Страница 7: ...in faucets shower heads Ensure water filter purifier is on separate line feed Check if pressure switch shutoff needs adjustment Pump Will Not Shut Off Runs When Faucet Closed Check output side pressur...

Страница 8: ...cument only unless Lippert Components provides explicit consent to distribute individual parts All manual information is subject to change without notice Revised editions will be available for free do...

Страница 9: ...Table des mati res Introduction 2 Liste de pi ces 2 Outils requis 3 Installation 3 Instructions g n rales d installation 3 Instructions de montage 3 Plomberie du syst me 4 Connexions lectriques 5 Assa...

Страница 10: ...e de service intermittent seulement Ne pas utiliser la pompe sur un syst me de filtration osmose inverse Le fonctionnement continu pression lev e peut r duire la dur e de vie de la pompe La pompe n es...

Страница 11: ...nnement Une fois le moteur refroidi le sectionneur se r enclenchera automatiquement 4 La pompe peut tre install e dans toutes les positions Toutefois si elle est install e verticalement la t te de la...

Страница 12: ...as sur des conduites d alimentation s par es Les r ducteurs de d bit des robinets et des t tes de douche Les conduites ayant un faible diam tre int rieur Les raccords et connexions restrictifs comme l...

Страница 13: ...llisante dans le r servoir et remplir le r servoir d eau potable 4 Ouvrir les robinets eau chaude et froide et laisser l eau couler jusqu ce que l odeur de chlore soit d cel e Fermer ensuite les robin...

Страница 14: ...erie Fermer ensuite la pompe 3 En utilisant un bac pour recueillir l eau restante retirer les tuyaux aux orifices d entr e et de sortie de la pompe 4 Ouvrir la pompe et la faire fonctionner jusqu ce q...

Страница 15: ...sserr es Succession de cycles rapide V rifier les restrictions au niveau de la plomberie et du d bit des robinets et t tes de douche S assurer que le filtre d eau et le purificateur se trouvent sur un...

Страница 16: ...able un consentement explicite de la part de Lippert Components pour distribuer des parties individuelles Tous les renseignements contenus dans le pr sent manuel peuvent tre modifi s sans pr avis Les...

Отзывы: