![Lippert Components Tire Linc Pressure Monitor 2.0 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/lippert-components/tire-linc-pressure-monitor-2-0/tire-linc-pressure-monitor-2-0_oem-installation-manual_1927333003.webp)
Rev: 04.13.21
Page 3
CCD-0002733
Repeater Dock Installation
1.
Locate a mounting area inside the unit that allows connection of the Tire Linc repeater dock (Fig. 1A)
to the unit's power source before the battery disconnect/constant power source without creating a
strain on the completed connection.
NOTE:
Connecting Tire Linc to a power source past the disconnect will turn off the Tire Linc system if the
power source is turned off during transport.
NOTE:
The Tire Linc repeater dock must be mounted vertically.
2.
Vertically orient the repeater dock and secure it to the wall with two OEM-supplied #8 self-tapping pan
head screws (Fig 1B).
3.
Make sure the unit's power is off, then connect the repeater dock's red power wire (Fig. 1C) and black
ground wire (Fig. 1D) to the unit as follows:
NOTE:
If necessary, use wire strippers to expose enough of the bare wire to make a good connection.
A.
Connect the repeater dock black wire to the unit ground wire.
B.
Connect the repeater dock red wire to a 12V DC power supply.
C.
Make sure that power and ground supply are fuse protected per RVIA standards and
OEM requirements.
Fig. 1
A
C
D
B
B