Harness Connections
Generator connections to the HVAC thermostat control (Fig. 5A, 6A) are via the 6-pin connector (Fig. 5B, 6B).
When wired into the "running signal" of the generator, the system tracks the total running hours of the
generator, and can be programmed to display an alert when the generator is due for scheduled maintenance.
NOTE:
The controller implements an automatic priming cycle at the beginning of the startup sequence. A
solenoid priming click will be heard a few seconds before the generator engine is started.
Fig. 5
Fig. 6
B
B
A
A
NOTE:
Figures 5 and 6 illustrate all harness connections to the controller.
1.
12V DC power and ground (Fig. 5C, 6C).
2.
CANBUS data wires (Fig. 5D, 6D)in proper sequence with OneControl system components.
3.
Wire harness to Zone 1 on controller (Fig. 5E, 6E), Zone 2 (Fig. 5F, 6F), Zone 3 (Fig. 6G) connected to
OneControl system designated zone.