Lippert Components COACH STEP Скачать руководство пользователя страница 2

+        -

DOOR SWITCH

B AT T E RY

POWER
SWITCH

TO FUSE

PANEL

6A FUSE

6A FUSE

CIRCUIT

PROTECTOR

BROWN

YELLOW

WHITE

RED

GREEN-
GROUND TO
CHASSIS

OPERATION

WARNING!

Look downwards toward the steps prior to exiting the coach.  It is possible to lock the steps in the retracted position.

Prior to exiting the coach, passengers must be sure steps are fully deployed.

STEP OPERATION - POWER “ON”
1.  Turn Power Switch to “ON” position.

2.  Open door.

3.  Steps will extend and lock when in the fully extended position.

4.  Amber entry lamp will illuminate automatically.

5.  Close door.

6.  Entry light will shut off and steps will retract.

INSTALLATION - DOOR SWITCH

Lippert Components, Inc. (LCI) recommends the use of the LCI supplied switch.  However, if another switch is to be used, it must be a switch held
open in the presence of a magnet and should have a triggering distance of no more than one inch.

Steps are designed to extend when the door switch closes (magnet is removed) and the switch completes the ground.

The Door Switch is ideally installed 6 inches above the floor on the hinge side of the door frame.  The magnet will be installed on the door
immediately opposite.  The distance between the magnet and the switch should be determined by trial unit the steps begin to extend when the door
is open around 6 inches.

Wires are best installed out of sight and away from sharp objects and potential snags.  It is very important that a good ground is supplied in an
area not likely to corrode, as this can contribute to step failure.

NOTE:  Installation of the Door Switch is a critical element in the installation of the step.  The switch must be installed so that any flexing of the
door frame does not cause the step to extend.  Conversely, the switch must trip early enough so when the door is opened, the steps extend prior to
the passenger exiting the coach.  The steps should begin extending prior to the door opening 6 inches.

Fig. 2

STEP LIGHT
SWITCH

Содержание COACH STEP

Страница 1: ...of the battery 5 Connect the BROWN WIRE to the NEGATIVE post of the battery WARNING Stepswillextendimmediately 6 Disconnect jumper wires from the battery INSTALLATION Steps must be installed using four 4 5 16 GR 8 bolts lock washer and nuts for the Automatic Elctric Steps and 3 8 bolts lock washers and nuts for the Automatic Electric Slideing Step Retract steps by attaching wires in the following ...

Страница 2: ...inch Steps are designed to extend when the door switch closes magnet is removed and the switch completes the ground The Door Switch is ideally installed 6 inches above the floor on the hinge side of the door frame The magnet will be installed on the door immediately opposite The distance between the magnet and the switch should be determined by trial unit the steps begin to extend when the door is...

Страница 3: ...eps can cause injury if proper precautions are not taken TROUBLESHOOTING THE SYSTEM 1 Disconnect the plug between the chassis and the steps Using a voltmeter measure the voltage on the large red wire at the chassis connector with the step switch in the ON position The meter should indicate more than 12VDC Turn the step switch to the OFF position and the meter should not indicate voltage If the met...

Страница 4: ...uts be used In no case should the step be welded to the vehicle This could result in warpage unreliable performance and electrical damage to the module D Service motor as an assembly It is strongly recommended that the motor gear be serviced as an assembly and this is the way replacements are sold The motor gear assembly can be replaced by disconnecting the two pin connector from the module to the...