background image

Rev: 06.15.18

Page 2

CCD-0001465

Installation

Note: 

All caulks, adhesives, sealants

 MUSt 

be compatible with ABS.

1. 

To avoid damage to apron, stand pan on side to install strainer.

2. 

Install strainer – excessive tightening of lock ring is not required and could cause damage to drain area. 

Do not use sharp object to remove excess caulk from around top of strainer.

3. 

Construct alcove with proper placement and construction of:

A. 

Access Hole: The size and shape may vary according to individual manufacturer. The access hole 

should be cut as small as possible to allow full support of the pan foam bottom at drain area. (1 1/2” 

of pan foam bottom extending over access cutouts is acceptable).

B. 

Threshold Support (if applicable): The front of the pan is to be supported. Material for construction 

should not exceed 1 1/2” overall thickness. (Note: Do not exceed 2 1/4” on 3548 and 3560 Pans.)

4. 

Set pan in place. Ensure bottom foam support sets securely on floor. Areas of importance are:

A. 

Floor

 MUSt 

be flat, level, and solid.

B. 

Apron is set properly into “F” strip.

C. 

Threshold support at proper height.

Note: 

If shim is used for proper floor contact, it should support the entire foam base of pan. Partial shims 

should not be used and pan should be level for proper drainage.

5. 

Secure pan to walls using flat-back non-rusting screws. It is suggested that pan not be secured until 

the alcove walls are in place and secured. Ensure alcove walls are plumb, straight, and square before 

securing pan flanges. Flange stress, bowl deflection, and/or bottom deflection can result from moving 

or repositioning a wall with the pan partially attached.

6. 

Flat-back non-rusting screw method;

A. 

If wall does not touch flange, a shim should be used to prevent flange distortion.

B. 

Pre-drill oversized hole for screws

C. 

Stand in pan while installing screws.

D. 

Use flat-back non-rusting screws

e. 

Use only two (2) screws per flange

F. 

Screws are to be inserted 90 degrees to the wall in center of flange.

G. 

Do not screw through corners (minimum 3” from corners).

H. 

Tighten the screw until the screw back touches the flange and stop. Do not over tighten so as to 

distort/stress the flange.

7. 

Connect drain line to pan strainer after installation is complete. P-trap should connect to strainer or tail 

piece without requiring force or causing back pressure to drain line.

8. 

Clean properly. Do not use any non-recommended cleaners (see “Care and Cleaning Instructions”).

Failure to follow the instructions provided in this manual may result in injury, component damage, or 

voiding of the component warranty.

Safety Information

LCI recommends that installations only be done by a qualified technician. LCI also recommends that the 

technician should use appropriate personal protective equipment, such as safety glasses and gloves, during 

the installation process.