background image

Wiring your CW-80 Transformer

7

Caution!

U

120/60z

0~18VAC

A

B

U

0~18VAC

TRACK ACCESSORY

Figure 3. Controller connections

Controller operations

FasTrack terminal section

Notch

Spade-shaped
connector

F

or best performance on large layouts, it is recommended that you use 16-gauge wire to con-
nect your CW-80 Transformer to the track. Connect the spade connectors on the wires from the

FasTrack terminal section. On larger layouts where several track connections are required, the use
of separate junctions/terminal strips (available at your local electronics store) is recommended to
prevent voltage drops. As your layout expands, you may also make power connections with the
stripped ends of the wires or banana plugs, placing no more than two wires on each terminal.

Make sure that all connections are secure. Loose connections can produce extremely high

temperatures. For this reason, do not touch the terminals or track connections during use.
Also, do not locate scenery materials such as lichen or ground foam near the terminals.

To prevent the excessive build up of heat, be sure to select the proper wire gauge
for your layout. Follow these guidelines:

• Track connections must be made with 18-gauge wire or heavier. Larger layouts

require a minimum of 16-gauge wire.

• Use 24-gauge wire only when connecting single accessories that require lower

current.

• When wiring multiple accessories (two or more) or accessories that require

higher current, be sure to use 18- to 16-gauge wire.

1.  Feed the wires through the notch in the FasTrack terminal section. 

Refer to

Figure 3.

2.  Loosen the red TRACK thumbscrew terminal, then slide the spade-shaped

connector at the end of the RED wire into position. 

The thumbscrew post

should be positioned between the “blades” of the spade connector. Tighten the thumbscrew
to secure the connection.

3.  Loosen the black TRACK thumbscrew terminal, then slide the spade-

shaped connector at the end of the BLACK wire into position. 

Tighten the

thumbscrew to secure the connection.

4.  If you need to power an accessory, connect the accessory to the

ACCESSORY thumbscrew terminals.

5.  Plug the CW-80 Transformer into your wall outlet (120 volts).

Содержание Pennsylvania Flyer Ready-to-Run Set

Страница 1: ...ner s Manual CAUTION ELECTRICTOY NOT RECOMMENDED FOR CHILDREN UNDER EIGHTYEARS OFAGE ASWITH ALL ELECTRIC PRODUCTS PRECAUTIONS SHOULD BE OBSERVED DURING HANDLINGANDUSETOREDUCETHERISKOFELECTRICSHOCK TRA...

Страница 2: ...and maintain your train set for years of reliable operation The transformer included with this set should be periodically examined for conditions that may result in the risk of fire electric shock or...

Страница 3: ...perating your CW 80 Transformer safely 6 Installing your CW 80 Transformer 6 Wiring your CW 80 Transformer 7 Operating your trains with the CW 80 Transformer 8 Experiencing the features of the CW 80 T...

Страница 4: ...ovides some examples of layouts that you can build with these track sections By adding more FasTrack track sections you can create an endless number of exciting track arrangements for more fun action...

Страница 5: ...s together securely so you always get good electrical contact Take a look at Figure 2 to show you how to join the track sections 1 Line up your two sections of track 2 Insert the rail tabs into the op...

Страница 6: ...nsformer only for its intended purpose The CW 80 Transformer was meant to operate on 120 volt 60 Hertz power Do not connect this product to any other power supply Do not operate the CW 80 Transformer...

Страница 7: ...als such as lichen or ground foam near the terminals To prevent the excessive build up of heat be sure to select the proper wire gauge for your layout Follow these guidelines Track connections must be...

Страница 8: ...at the power increases and decreases at a set rate For example quickly throwing the throttle all the way forward will not result in an instant increase to full power When operating in the conventional...

Страница 9: ...activate the reverse unit in your locomotive Your locomotive will not respond to this button when the reverse unit switch is in the OFF position WHISTLE HORN The WHISTLE HORN button will activate you...

Страница 10: ...any Railsounds equipped locomotive Press BELL to begin the sound again to stop it Direction Press the DIRECTION button to go forward or reverse or to place the locomotive in neutral no movement headl...

Страница 11: ...LL buttons on the Controller Refer to Figure 4 on page 10 for the location of these buttons The green light on the Transformer will flash and track power will turn off 4 With all three buttons held do...

Страница 12: ...cessory voltage are 0 16 volts AC each This Transformer is capable of operating trains up to and including dual motored AC engines To operate at this level of track power it may be necessary to discon...

Страница 13: ...been set too low for the accessory Refer to page 11 and reset the voltage to a higher level Locomotive runs slowly or lights dim at the far end of the track On larger layouts additional track resistan...

Страница 14: ...e with alternating current AC transformers only Move em out Get your locomotive moving To sequence the reversing unit press the Direction button on your transformer or turn the throttle OFF and back O...

Страница 15: ...the OFF position towards the rear of the locomotive the locomotive will be locked in the next mode of operation in the sequence For instance if the locomotive is moving forward then is stopped and the...

Страница 16: ...bling them to pull heavy loads at higher speeds Replacement Traction Tires are available at your authorized Lionel Service Center When coupling your cars at least one of the mating couplers must be op...

Страница 17: ...rules to keep in mind never over lubricate a small amount will do and avoid getting grease or oil on the locomo tive s wheels contact rollers or your track You ll know your locomotive requires lubrica...

Страница 18: ...comotive s stack Smoke production commences momentarily faster if you run your locomotive at high speed When smoke production wanes add more fluid 4 to 8 drops An idle locomotive will not smoke Smoke...

Страница 19: ...tion 3 Pull the lamp straight out and replace it with Lionel part no 600 0161 300 available from your nearest Lionel Authorized Service Center or from Lionel Service Be careful not to twist the lamp o...

Страница 20: ...from state to state Instructions for Obtaining Service If service for this Lionel L L C product is required bring the item along with your dated sales receipt and completed warranty information to th...

Отзывы: