LION NFPA 1975 Скачать руководство пользователя страница 15

15

WARNING

!

Your Pants is NOT designed to protect you against electrocution. When entering a 

rescue site, you should NEVER touch live wiring, especially if your Pants is wet. Never 

allow equipment you are operating to contact live wiring.

WARNING

!

Never Dry-Clean your Pants. Dry cleaning solvents are made from petroleum products, 

which may support combustion and negate the fabric’s flame resistant properties.

WARNING

!

To reduce the risk of harm from hazardous substances present at a building collapse, 

damaged vehicle,  or hazardous chemicals, you MUST wash your Pants.

WARNING

!

Always wash your NFPA 1951 Utility/NFPA 1977/NFPA 1975 Tri-Certified Pants 

separately from other items. Never wash your Pants at home, or at public laundry 

facilities to avoid the spread of chemical contamination or hazardous combustion 

products to other laundry.

  If you are unavoidably exposed to high temperatures during a Technical Rescue and/or 

Wildland Firefighting activity, you need to be constantly aware of the buildup of heat in 

the surrounding environment and in your Pants and be ready to escape to a cool area 

where you can remove hot Pants quickly to avoid burns.

!

DANGER

10.5 

LIQUID PENETRATION AND HAZARDOUS MATERIALS

 

No Protection Against Liquid Penetration or Hazardous Materials

  

10.6 ELECTROCUTION

10.7 

BLOODBORNE PATHOGENS

 

Your Pants are not designed to protect against the hazards of exposure to bloodborne 

pathogens present in body fluids. See Section 11 of this Guide for more information.

10.8 

ADDITIONAL FACTORS AFFECTING SAFETY

 

The following additional factors may affect the limited protection provided by  
the Pants:

• 

Conditions at the incident beyond the Pants’ scope of the limited 

purposes; 

• 

Unauthorized modifications, repairs or replacement of components of  

the Pants not otherwise in compliance with LION’s specifications; and 

• The 

addition of accessories that are not approved by LION as 

compatible with NFPA 1951 Utility/NFPA 1977/NFPA 1975 Tri-Certified 

Pants. If you have questions about whether accessories will degrade  

the performance of your Pants below the NFPA 1951 Utility,  

NFPA 1977, or NFPA 1975 Standard, contact LION.

11. 

WASHING, DECONTAMINATION AND  
DISINFECTION

11.1  

FREQUENCY

 

NFPA 1951 Utility/NFPA 1977/NFPA 1975 Tri-Certified Pants should be cleaned:  

1.) after every use and;  

2.) as soon as possible after exposure to smoke, products of combustion or 

hazardous substances.

Содержание NFPA 1975

Страница 1: ...bels before wearing Skin burns can occur when skin reaches a temperature of 118 F 47 8 C Fire burns at temperatures up to 2000 F 1093 3 C or higher These Pants provide limited protection against flash...

Страница 2: ...A 1951 Utility NFPA 1977 NFPA 1975 Tri Certified Pants Questions write or call immediately LION 7200 Poe Ave Suite 400 Dayton OH 45414 Info LIONprotects com 1 800 421 2926 FI6685 255 CLEANING AND STOR...

Страница 3: ...rotective Clothing and Equipment for Wildland Firefighting and NFPA 1975 Standard on Work Apparel for Emergency Services This User Instruction Safety and Training Guide gives important instructions re...

Страница 4: ...t can consist of biologically derived toxins or pathogens to inflict lethal or incapacitating casualties Body Fluids Fluids produced by the body including but not limited to blood semen mucous feces u...

Страница 5: ...977 NFPA 1975 Tri Certified Pants The term Pants used throughout this Guide refers ONLY to those certified for use in Technical Rescue and Wildland Operations NFPA 1951 Utility NFPA 1977 NFPA 1975 Tri...

Страница 6: ...cave in of a trench A trench is deeper than it is wide Useful Life The period of time that NFPA 1951 Utility NFPA 1977 NFPA 1975 Tri Certified Pants which have been properly cared for can be expected...

Страница 7: ...to assume the risks and responsibilities listed in the Personal Responsibility Code See FIG 1 and back cover of this Guide Yes No If you answered NO to any of the questions DO NOT WEAR THIS GARMENT u...

Страница 8: ...ction see Definitions should perform a risk assessment to identify the hazards present and to determine the suitability of the NFPA 1951 Utility NFPA 1977 NFPA 1975 Tri Certified Pants For each of the...

Страница 9: ...el explains washing drying and storage instructions In addition the Pants Information Label located on the centre back inside the garment lists the Pants model and the date of manufacture Samples of t...

Страница 10: ...ould require replacement Check stitching for loose threads that would require repair c Hardware Examine all hardware i e zippers hook and loop and buttons for corrosion or other damage that would requ...

Страница 11: ...T Never wear Pants that fit improperly If you have a question or there is a problem with the fit of the Pants contact your safety officer for assistance Wearing a Pants that does not fit properly coul...

Страница 12: ...of an ignitable liquid without the production of damaging pressure Flash fires mainly produce hazardous radiant heat as well as convective heat Always wear clean and thoroughly dry Pants Soiled or co...

Страница 13: ...nts damage to warn of imminent burns Always be aware of your surrounding environment and be ready to escape if you begin to feel tingling or burning sensations DANGER Technical Rescue and or Wildland...

Страница 14: ...vascular exercise abstaining from cigarette smoking proper training a healthy diet and avoidance of obesity can help to reduce the risk of heart attack 10 3 HEAT STRESS A SIGNIFICANT CAUSE OF RESPONDE...

Страница 15: ...area where you can remove hot Pants quickly to avoid burns DANGER 10 5 LIQUID PENETRATION AND HAZARDOUS MATERIALS No Protection Against Liquid Penetration or Hazardous Materials 10 6 ELECTROCUTION 10...

Страница 16: ...gent that is safe for use on protective clothing fabrics to clean light spots and stains on Pants B Apply the cleaner one or two times on soiled areas according to the cleaning agent manufacturer s in...

Страница 17: ...wash your Pants as thoroughly and the agitator will damage the Pants and reduce its durability and protective value The following machine settings should be used A Wash temperature should be 105o F B...

Страница 18: ...tandard for Fire Department Infection Control Program Preparation Remove contaminated and infected NFPA 1951 Utility NFPA 1977 NFPA 1975 Tri Certified Pants from wearer and from service before beginni...

Страница 19: ...risk of cancer or other diseases 14 RETIREMENT 14 1 USEFUL LIFE AND RETIREMENT NFPA 1951 Utility NFPA 1977 and NFPA 1975 performance requirements are based on new unworn Pants and Composites Useful l...

Страница 20: ...depending on Pants materials selected conditions of wear maintenance and storage but is normally 4 years Pants more than five 5 years old and made to earlier versions of the NFPA Standard are highly...

Страница 21: ...l life is the period of time that Garments which have been properly cared for can be expected to provide reasonable limited protection The useful life will vary according to type and frequency of use...

Страница 22: ...22 NOTES...

Страница 23: ...ities can include Routine or Advanced Inspection Cleaning Decontamination Repair Alteration Removal from Service Retirement Disposal etc Date of Retirement________________________ Date and Method of D...

Страница 24: ...he use precautions and care of any equipment you may be called upon to use 4 It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate a...

Отзывы: