MAXTXRETRY - Maximum Transmit Retries
Volatile Address = 0x52; Non-Volatile Address = 0x07
The value in the MAXTXRETRY register sets the number of transmission
retries performed if an acknowledgement is not received. If an
acknowledgement is not received after the last retry, exception EX_
NORFACK is raised. Figure 51 shows examples of the command.
The time between retries depends on the current baud rate. Figure 52
shows the time between retries based on baud rate. The elapsed transmit
and acknowledgment time is (1) × (PacketTransm Timeout).
Figure 51: HumPRO-A
TM
Series Maximum Transmit Retries Command and Response
HumPRO-A
TM
Series Acknowledgement Timeout Times
Baud Rate
Timeout Time
9,600
50ms
19,200
50ms
38,400
30ms
57,600
30ms
115,200
30ms
Figure 52: HumPRO-A
TM
Series Acknowledgement Timeout Times
HumPRO-A
TM
Series Maximum Transmit Retries
Read Command
Read Response
Header
Size
Escape
Address
ACK
Address
Value
0xFF
0x02
0xFE
0x52
0x07
0x06
0x52
0x07
V
Write Command
Header
Size
Address
Value
0xFF
0x02
0x52
0x07
V
DATATO - Transmit Wait Timeout
Volatile Address = 0x50; Non-Volatile Address = 0x05
When a byte is received from the UART, the module starts a timer that
counts down every millisecond. The timer is restarted when each byte is
received. The value for the DATATO register is the number of milliseconds
to wait before transmitting the data in the UART receive buffer. The default
setting for this register is 0x10 (~16ms delay).
If the timer reaches zero before the next byte is received from the UART,
the module begins transmitting the data in the buffer. This timeout value
should be greater than one byte time at the current UART baud rate with a
minimum of 0x02. It should not be set any value less than one byte time as
unpredictable results could occur.
If the timeout value is set to 0x00, the transmit wait timeout is deactivated.
In this case, the transceiver waits until a number of bytes equal to the
UART Byte Count Trigger (
) have been received by the UART. All
of the bytes are sent once the trigger has been reached. Figure 49 shows
examples of the commands. Figure 50 shows the minimum timeout values
based on baud rate.
Figure 49: HumPRO-A
TM
Series Transmit Wait Timeout Command and Response
HumPRO-A
TM
Series Minimum DATATO Values
Baud Rate
Minimum DATATO
9,600
3ms
19,200
2ms
38,400
2ms
57,600
2ms
115,200
2ms
Figure 50: HumPRO-A
TM
Series Transmit Wait Timeout Minimum Values
HumPRO-A
TM
Series Transmit Wait Timeout
Read Command
Read Response
Header
Size
Escape
Address
ACK
Address
Value
0xFF
0x02
0xFE
0x50
0x05
0x06
0x50
0x05
V
Write Command
Header
Size
Address
Value
0xFF
0x02
0x50
0x05
V