background image

Front IR receiver

Front Wide-Angle High-Power InfraRed Transmitter

Aux, 6 pin modular connector

Communication, DB09 connector

Output, 3.5 jack connector

Depending on the typenumber, your TableTop device is equipped with an InfraRed
receiver accepting signals in the 36-40 KHz or 455 KHz range.

3 pcs. built-in InfraRed emitter diodes sends the InfraRed signal.

12 volt output, 2 pcs. ground active inputs, 1 pcs. 5 volt active output.
Can be used as interface to external devices as for example an X10 modem XM10E.

Holds computer and bus-system communication signals, digtial input and output.
When the software detects reception of expected data, an command is send
on the communication line (optional computer RS232 or bus-system RS485).
Transmitter and converter products can be commanded to transmit specific
data-signals.
Please see our "Open protocol" for more information.

Anything transmitted by the front wide-angle high-power InfraRed transmitter
is automatically copied to this low-power output.
This allows you to distribute for example InfraRed codes to many devices by
adding a distribution block and a number of external IR emitters.

Input, 3.5 mm jack connector

Accepts 5 volt data signals from any source. For example demodulated codes
from an InfraRed or RadioFrequency receiver.
Allows you to build an external receiver and store your TableTop product away.

Output Power

Communication

Input

Output Power

Communication

Input

InfraRed receiver and transmitter in the front

Output Power

Communication

Input 

Aux

Updated: 090413

h t t p : / / w w w . l i n t r o n i c . d k

LinTronic

Содержание TableTop Series

Страница 1: ...Receives Transmits and Converts InfraRed RadioFrequency RS232 RS485 X10 IR Tx IR Tx IR Rx IR Tx TableTop series Hardware version 5 h t t p w w w l i n t r o n i c d k Updated 170805 LinTronic...

Страница 2: ...wer output for external InfraRed emitters Accepts 9 18 volt DC Polarity protected For reception and RS232 RS485 communication only a power supply capable of delivering 100 mA is sufficient For high po...

Страница 3: ...tional computer RS232 or bus system RS485 Transmitter and converter products can be commanded to transmit specific data signals Please see our Open protocol for more information Anything transmitted b...

Страница 4: ...Circuit boards dimensions 8 7 6 5 4 3 2 1 ON 59 mm 93 mm 3 mm 3 mm 16 mm Updated 090413 h t t p w w w l i n t r o n i c d k LinTronic...

Страница 5: ...8 7 6 5 4 3 2 1 ON RS232 RS485 Factory default Switchblock and jumpers InfraRed Receivers 36 40 KHz 455 Khz Updated 090413 X10 port h t t p w w w l i n t r o n i c d k LinTronic...

Страница 6: ...raRed Digital Inputs 5 volt pulled up 100K Digital Outputs active low 5 volt pulled up Programmable reaction computer monitored Relay contacts AutoMutic Relay PIR movement sensor switches etc Gnd Gnd...

Страница 7: ...B C Jack connector seen from solderside 1 C Ground 2 A 5 volt 3 B IRsignal 455 KHz B O 8087030 1 2 3 4 5 PL A SM A PRO TEC TED External Receiver Updated 090413 h t t p w w w l i n t r o n i c d k Lin...

Страница 8: ...If you want test the Low Power External IR Output you can connect a normal visible LED to a mono 3 5 mm jack connector and insert it the External IR Output TT IR ET03 TableTop Transmitter or Converte...

Страница 9: ...ut pin 1 must be grounded 100K Digital Inputs Updated 170805 h t t p w w w l i n t r o n i c d k LinTronic 5 4 3 2 1 9 8 7 6 Digital Input 2 5 volt 4 5 The digital Input is internally pulled up by a 1...

Страница 10: ...n be removed if required to control 12 volt relay The transistor output is current controlled by the 22 Resistor If relay does not activate you need to shorten the 22R resistor to allow bigger current...

Страница 11: ...Output 2 Output 1...

Страница 12: ...epeater See website LIG HT RA DIO TV CD DV D SA T VT AP E RE CO RD AT AP E 9 8 7 6 5 4 3 2 1 ME NU 0 TE XT GO EX IT LIS T ST OP BAN G OLU FSEN TT IR 8087030 or TT IR 1455 ROOM A ROOM B Updated 090413...