5. Ordering Information 

H X - 0 1 0 0 C   -   8 8   V R 1   N   D 0 5   T 3 5   N N N  

     

            [1]

 

                                                                           

[2]

 

 

[3]    [4]

 

     

[5] 

 

   

[6]

 

    [7] 

 

[1] HX: Heat Exchanger Series 

    0100C: 100SLM,

 

0300C: 300SLM 

[2] Fitting size 

88: IN 12.7mm, OUT 12.7mm 

[3] Fitting type 

VR1: VCR [IN male, OUT female] 

[4] Internal treatment   

N: No polishing 

[5] Heater type 

    HX-0100C (Selectable) 

    D05: AC120V 700W, 

 

D06: AC240V 875W 

HX-0300C 

    D06: AC240V 2100W 

[6] Thermal switch 

T35: 350 ºC ± 9ºC 

[7] Option   

NNN: Standard specification 

6. Connection 

(1)    Heater/ Thermal switch Connectors 

Equipped Connector             

     

: SRCN6A16-7P (JAE) 

Applicable Connector (plug)

               

: SRCN6A16-7S (JAE) 

Pin No.

 

Signal name

 

Inner block Heater 

Outer block Heater 

Case Gnd. 

Thermal switch 

(2)    Inner block Connectors 

Equipped Connector

 

  : CMP03-K (RKC Instrument Inc.) 

Applicable Connector 

       

: CMP01-K (RKC Instrument Inc.) 

Pin No.

 

Signal name

 

K Type Thermocouple (-) 

K Type Thermocouple (+) 

(3)    Outer block Connectors 

Equipped Connector 

       

: CMP03-K (RKC Instrument Inc.) 

Applicable Connector : CMP01-K (RKC Instrument Inc.)   

Pin No.

 

Signal name

 

K Type Thermocouple (-) 

K Type Thermocouple (+) 

7. Preparation and Operational Procedure   

 

(1)

 

Please  prepare  two  temperature  control  units.

 

There  are  two  points  which 

require temperature control. 
[HX-0100C] 
  D05:120V

 

Outer block 400W,    Inner block 300W 

  D06:240V

 

Outer block 500W,    Inner block 375W 

[HX-0300C] 
  D06:240V

 

Outer block 1200W,    Inner block 900W 

Please  take  care  with  respect  to  the  heater  capacities.  In  addition, 
temperature  control  unit  with  built-in  safety  mechanisms  is  recommended 
for temperature control point. As the built-in thermocouple is K type, please 
select unit which is compatible with this type of thermocouple. 

(2)

 

Please be sure to use safety devices such as circuit breakers to prevent surge 
currents and short circuits.   

(3)

 

Please  be  careful  to  attach  this  device  in  the  direction  of  the  gas  flow.  In 
order  to prevent  a  decrease in  the gas  temperature  after heat exchange  has 
taken place, please heat the piping between the gas outlet and the next piece 
of machinery. 

(4)

 

Please  carry  out connections  according to the  connector  table. This  device 
has a built-in 350 ºC thermal switch.   

(5)

 

The  heater  can  be  affected  by  humidity  during  storage.  Ensure  that 
insulation  resistance  is  above  20M  ohm.  If  the  insulation  resistance  drops 
below 20M ohm, dry the HX and ensure that insulation resistance is above 
20M ohm.   

(6)

 

Supply  power,  set  the  temperature  to  the  desired  value  using  the 
temperature  control  units  and  allow  60  minutes  for  the  device  to  stabilize 
after  the  set  temperature  has  been  reached.  Even  though  the  temperature 
control unit display temperature may be stable the temperature of the body 
of  the  device  is  not.  In  order  to  achieve  good  heat  exchange  efficiency 
please allow this device to stabilize before use.   

(7)

 

Estimated gas temperatures can be found from the graphs in the upper right. 
However,  this  data  is  for  nitrogen  gas  and  should  not  be  applied  as  is  to 
gases other than nitrogen. Please use this data only as a guide. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                               

·Gas: N2 

             

       

·Operating temperature: 20ºC 

 

8. Product Warranty   

(1) 

 

Period 

This product is guaranteed for 1 year from the date of shipment.   
Defects are repaired according to the following regulations.   

 

(2) 

 

Scope 

Warranty coverage is restricted to this product only. Any other damage caused 
by this product is not covered. 

 

(3) 

 

Disclaimer facts 

 

 

 

The following repairs are not covered by the warranty: 

1) Failure caused by product of gas or liquid used. 
2) Failure caused by misuse (including careless operation), incorrect repair or modification. 
3) Failure cause by falling or dropping after purchase. 
4) Failure caused by fire, earthquake, flood, lightning, or other natural disasters. 

 

Even if the warranty period is still in effect, repair service may not be provided 
in the following cases.   

1) When the kind of fluid used in the product is unclear. 
2) The product is returned with fluid remaining inside, and safety cannot be confirmed. 

 

  This instruction manual is subject to revision without notice. 
 

 

 

 

 

                 

       

http://www.lintec-mfc.co.jp 

Corporate Headquarters 

4-1-23 Sekinotsu, Otsu City, Shiga Pref. 520-2277, Japan

 

TEL.

 

+81-(0)77-536-2210 FAX. +81-(0)77-536-2215 

Tokyo Branch Office

 

3F Hattori Build., 4-30-14 Yotsuya Shinjyuku-ku Tokyo 160-0004, Japan

 

TEL.    +81-(0)3-5366-2801 FAX. +81-(0)3-3341-3513 

ガス加熱器HX-101温度特性

Temperature characteristics of HX101

50

70

90

110

130

150

170

190

210

230

250

270

290

50

100

150

200

250

300

350

設定温度(Set temperature) ℃

゙ス

(G

as

 t

em

p

e

rat

u

re

 a

e

xi

t)

10slm

20slm

30slm

40slm

50slm

60slm

70slm

80slm

90slm

100slm

ガス加熱器

HX-0100C

温度特性

 

Temperature characteristics of HX-0100C 

ガス加熱器HX-101温度特性

Temperature characteristics of HX-101-L300

50

100

150

200

250

300

50

100

150

200

250

300

設定温度 ℃

Set temperature

 

T

em

pe

ra

tur

at

 ex

it

10slm

20slm

50slm

100slm

200slm

300slm

ガス加熱器

  HX-0300C 

温度特性

 

Temperature characteristics of HX-0300C 