5. Ordering Information
H X - 0 1 0 0 C - 8 8 V R 1 N D 0 5 T 3 5 N N N
[1]
[2]
[3] [4]
[5]
[6]
[7]
[1] HX: Heat Exchanger Series
0100C: 100SLM,
0300C: 300SLM
[2] Fitting size
88: IN 12.7mm, OUT 12.7mm
[3] Fitting type
VR1: VCR [IN male, OUT female]
[4] Internal treatment
N: No polishing
[5] Heater type
HX-0100C (Selectable)
D05: AC120V 700W,
D06: AC240V 875W
HX-0300C
D06: AC240V 2100W
[6] Thermal switch
T35: 350 ºC ± 9ºC
[7] Option
NNN: Standard specification
6. Connection
(1) Heater/ Thermal switch Connectors
Equipped Connector
: SRCN6A16-7P (JAE)
Applicable Connector (plug)
: SRCN6A16-7S (JAE)
Pin No.
Signal name
1
Inner block Heater
2
3
Outer block Heater
4
5
Case Gnd.
6
Thermal switch
7
(2) Inner block Connectors
Equipped Connector
: CMP03-K (RKC Instrument Inc.)
Applicable Connector
: CMP01-K (RKC Instrument Inc.)
Pin No.
Signal name
K
K Type Thermocouple (-)
+
K Type Thermocouple (+)
(3) Outer block Connectors
Equipped Connector
: CMP03-K (RKC Instrument Inc.)
Applicable Connector : CMP01-K (RKC Instrument Inc.)
Pin No.
Signal name
K
K Type Thermocouple (-)
+
K Type Thermocouple (+)
7. Preparation and Operational Procedure
(1)
Please prepare two temperature control units.
There are two points which
require temperature control.
[HX-0100C]
D05:120V
Outer block 400W, Inner block 300W
D06:240V
Outer block 500W, Inner block 375W
[HX-0300C]
D06:240V
Outer block 1200W, Inner block 900W
Please take care with respect to the heater capacities. In addition,
temperature control unit with built-in safety mechanisms is recommended
for temperature control point. As the built-in thermocouple is K type, please
select unit which is compatible with this type of thermocouple.
(2)
Please be sure to use safety devices such as circuit breakers to prevent surge
currents and short circuits.
(3)
Please be careful to attach this device in the direction of the gas flow. In
order to prevent a decrease in the gas temperature after heat exchange has
taken place, please heat the piping between the gas outlet and the next piece
of machinery.
(4)
Please carry out connections according to the connector table. This device
has a built-in 350 ºC thermal switch.
(5)
The heater can be affected by humidity during storage. Ensure that
insulation resistance is above 20M ohm. If the insulation resistance drops
below 20M ohm, dry the HX and ensure that insulation resistance is above
20M ohm.
(6)
Supply power, set the temperature to the desired value using the
temperature control units and allow 60 minutes for the device to stabilize
after the set temperature has been reached. Even though the temperature
control unit display temperature may be stable the temperature of the body
of the device is not. In order to achieve good heat exchange efficiency
please allow this device to stabilize before use.
(7)
Estimated gas temperatures can be found from the graphs in the upper right.
However, this data is for nitrogen gas and should not be applied as is to
gases other than nitrogen. Please use this data only as a guide.
·Gas: N2
·Operating temperature: 20ºC
8. Product Warranty
(1)
Period
This product is guaranteed for 1 year from the date of shipment.
Defects are repaired according to the following regulations.
(2)
Scope
Warranty coverage is restricted to this product only. Any other damage caused
by this product is not covered.
(3)
Disclaimer facts
The following repairs are not covered by the warranty:
1) Failure caused by product of gas or liquid used.
2) Failure caused by misuse (including careless operation), incorrect repair or modification.
3) Failure cause by falling or dropping after purchase.
4) Failure caused by fire, earthquake, flood, lightning, or other natural disasters.
Even if the warranty period is still in effect, repair service may not be provided
in the following cases.
1) When the kind of fluid used in the product is unclear.
2) The product is returned with fluid remaining inside, and safety cannot be confirmed.
This instruction manual is subject to revision without notice.
http://www.lintec-mfc.co.jp
Corporate Headquarters
4-1-23 Sekinotsu, Otsu City, Shiga Pref. 520-2277, Japan
TEL.
+81-(0)77-536-2210 FAX. +81-(0)77-536-2215
Tokyo Branch Office
3F Hattori Build., 4-30-14 Yotsuya Shinjyuku-ku Tokyo 160-0004, Japan
TEL. +81-(0)3-5366-2801 FAX. +81-(0)3-3341-3513
ガス加熱器HX-101温度特性
Temperature characteristics of HX101
50
70
90
110
130
150
170
190
210
230
250
270
290
50
100
150
200
250
300
350
設定温度(Set temperature) ℃
出
口
カ
゙ス
温
度
(G
as
t
em
p
e
rat
u
re
a
t
e
xi
t)
℃
10slm
20slm
30slm
40slm
50slm
60slm
70slm
80slm
90slm
100slm
ガス加熱器
HX-0100C
温度特性
Temperature characteristics of HX-0100C
ガス加熱器HX-101温度特性
Temperature characteristics of HX-101-L300
50
100
150
200
250
300
50
100
150
200
250
300
設定温度 ℃
Set temperature
出
口
ガ
ス
温
度
℃
T
em
pe
ra
tur
e
at
ex
it
10slm
20slm
50slm
100slm
200slm
300slm
ガス加熱器
HX-0300C
温度特性
Temperature characteristics of HX-0300C