Insert tap fitting and assemble 

related parts.

Figure 2

Figure 3

Connect tubing between tap 

fitting and alarm module.

Figure 4

Cut tubing length to minimize 

any sag. Proceed to calibrate 

unit (step 5). 

Figure 5

Incorrect

Correct

Sag

Installing the LintAlert®

Installation and calibration is a fairly quick and straight forward process. 

Step One

Confirm  that  the  in-the-wall  duct  system  has  been 

completely  cleaned  and  in  like-new  condition  (read 

Notice  on  reverse  side).   

In-O-Vate  Technologies,  as 

well as the leading dryer manufacturers, strongly recommend using a 

transition  hose  that  is  UL2158A  listed,  like  DryerFlex™  or  semi-rigid 

aluminium flex. The wire bound foil flex, although not as efficient, will 

work comparably with the LintAlert. If you have white vinyl flex, please 

take this opportunity to replace it, as it’s been well documented to be 

extremely unsafe and associated with many dryer fires.    

Step Two

Disconnect  the  new  or  existing  exhaust  hose  from  where 

it  connects  to  the  exhaust  port  on  the  back  of  the  dryer. 

Favoring the middle to outside radius of the flex, 

carefully 

poke a 

¼” 

hole in the hose, 4"-6" away from where the exhaust 

port connects. 

(Figure 1)

.

  Be sure to leave room for the flex hose to 

re-secure to the dryers’ exhaust terminal.  

Step Three

Take the umbrella shaped tap fitting, (Figure 3 - A) and slide 

it up inside the exhaust hose and through the hole you just 

made. It is important to rotate the fitting so that the curved 

contour of the fitting matches that of the transition hose. The felt washer 

(B) will go on next, followed by the curved washer (C). Finally, twist the 

nylon thumb-nut on and finger tighten to ensure that no air can escape 

(Figure 4).  Connect one end of the clear vinyl tubing to the tap fitting 

(while supporting it from within the flex hose) and reattach the existing 

exhaust hose to the dryer’s exhaust port.

Step Four

Move the dryer back into place and plug the alert module 

into  the  nearest  un-switched  110v  AC  power  outlet 

prior 

to attaching the tubing to the barb

.  Important Note: Cut 

the length of the clear vinyl tubing to minimize any sag or droop in the 

tubing, as this could allow condensation build-up within the tubing to 

puddle thus creating an air block (Figure 5).  Insert tubing over hose 

barb on LintAlert.  

Step Five [Calibration]

Clean the dryer’s lint screen. Begin a drying cycle with NO 

clothes in the drum and at your usual temperature setting.  

While the dryer is running, press and hold the LintAlert 

button for about 6 seconds, until all five LEDs progressively light 

up and you hear a chime tone (records “clean value” pressure 

level).

  After about 2 seconds, you should observe that the first green 

LED is illuminated and the logo lens, “LintAlert,” is steady blue.  Note: 

Any subsequent calibration attempts will require an approximate 12 

second press of the button. The LintAlert should now be in a normal 

monitoring mode. Refer to the troubleshooting section of this manual 

or online if this normal state is not observed.  
Troubleshooting Section: 

Notice:

 Works on all dryers except those with booster fans, dual motor 

technology and dryers that share exhaust systems like those typically found 

in high-rise structures. 

Tubing does not reach:

 The tubing can be extended or replaced with 

similar  diameter  tubing.  We  offer  longer  tubing  lengths  in  our  online 

store,  but  the  same  tubing  (1/8”  ID  ¼”  OD)  is  usually  available  at 

aquarium or pet outlets. Results with lengths up to 24 feet were shown 

to be consistent. It is important that the tubing placement and type of 

tubing prohibit being pinched or kinked.  

No 110v outlet near my dryer: 

In most cases, the washer and dryer 

reside side by side, and the washer uses 110v. If the washer outlet is 

hidden or too far from the dryer’s location, then the first suggestion is 

to extend the tubing (see above). The second alternative would be to 

purchase and mount a multi outlet power bar above the dryer for the 

LintAlert to plug into.

LED Display During Calibration:

means no pressure was observed, either due to dryer not 

ON, tubing not connected or LintAlert was plugged in with 

tubing connected and dryer running.  In the latter case, 

Factory Reset (see below).  

means too much pressure was present, likely the exhaust 

duct was never cleaned or there still exists blockage of some 

sort (e.g., inefficient vent hood).

means calibration was successful and after 2 seconds the 

first LED will illuminate.  

Monitoring Mode:

dryer not ON or tubing detached.

normal (recent calibration), 

approx. 20% blocked, 

approx. 32% blocked, 

approx. 45% blocked, 

approx. 60% blocked.

Restore to Original Calibration Level:

 Unplug the unit for 3 seconds 

and insert back into plug.

Factory Reset:

 With dryer off, unplug LintAlert then plug back in while 

pressing button and continue to hold till chime is heard (approx. 2 secs).
Additional troubleshooting guides and updated manuals can be found online. 

See FAQs online and on the product packaging.