background image

Thank you for purchasing the Linortek ITrixx­WFMN Wireless Hour Meter. The iTrixx is an IoT controller and runtime meter with 

digital inputs, analog inputs and relay outputs capable of tracking runtime hours of up to two different pieces of equipment. For the 

complete setting instructions, please refer to the iTrixx­WFMN Owners and Operation Manual, which can be downloaded here:
https://www.linortek.com/downloads/documentations/
W

HAT

'

S

 

IN

 

THE

 B

OX

Please inspect the contents of your product kit. Each SERVER is sent in its own box and includes:
____One iTrixx WFMN SERVER 
____One 12VDC Power Supply 
____2 Wago Connectors 
____One 2.2k Ohm Resistor Kit
____iTrixx WFMN Quick Setup Instruction

I

T

RIXX

­WFMN W

IRE

 C

HART

There is 1 cable on the iTrixx­WFMN­Di, and 3 cables on the iTrixx­WFMN­ADi. From the top to bottom, they are marked as cable 1, 

2, 3. See the chart below for explanation.

Cable 1: Analog Inputs (for iTrixx­WFMN­ADi only)

Cable 2: Relay Outputs (for iTrixx­WFMN­ADi only)

Cable 3: Digital Inputs and Power Input

Wire Color

Function

Note

Green

Ain1

Analog 1

Brown

Return

Red

5V

If 12V sensor, us a 12V power supply

White

Ain2

Analog 2

Blue

Return

Black

5V

If 12V sensor, us a 12V power supply

Wire Color

Function

Note

Brown

Relay 1 NC

Relay 1

Green

Relay 1 C

Red

Relay 1 NO

Blue

Relay 2 NC

Relay 2

White

Relay 2 C

Black

Relay 2 NO

iTrixx­WFMN­Di Hardware

iTrixx­WFMN­ADi Hardware

1

ITRIXX­WFMN QUICK SETTING INSTRUCTION

Содержание ITRIXX-­WFMN

Страница 1: ... Supply ____2 Wago Connectors ____One 2 2k Ohm Resistor Kit ____iTrixx WFMN Quick Setup Instruction ITRIXX WFMN WIRE CHART There is 1 cable on the iTrixx WFMN Di and 3 cables on the iTrixx WFMN ADi From the top to bottom they are marked as cable 1 2 3 See the chart below for explanation Cable 1 Analog Inputs for iTrixx WFMN ADi only Cable 2 Relay Outputs for iTrixx WFMN ADi only Wire Color Functio...

Страница 2: ...will count for iTrixx WFMN ADi unit only The relays on the iTrixx WFMN ADi are dry contact relays and normally open Most common use case is to wire a digital input to the same power source of your iTrixx Server to trigger the meter so when your equipment is on iTrixx is counting MAKE CONNECTIONS Relay Connection iTrixx WFMN ADi Your iTrixx WFMN ADi server has two 5VDC relay outputs These relays ar...

Страница 3: ...supply for initial setup and software configuration Once your initial setup is completed you can wire your iTrixx to your equipment by tapping into a 12 48 VDC circuit on your equipment To connect iTrixx to the 12VDC power supply connect the RED wire on Cable 3 to the positive wire of the power supply BLACK wire There are two modes of operation for the digital inputs ISOLATED and PULL UP These are...

Страница 4: ...ure your browser doesn t change http to https 6 Enter the name of your WiFi network under Network Name and your WiFi password under Pass phrase 7 Click Connect The Blue LED on your device will stop blinking and stay on solid Your iTrixx server is now connected to your network at this time your computer should connect back to your network If it s not automatically switched to your network click the...

Страница 5: ...the following pages IMPORTANT NOTE Make certain to use the save command after making changes otherwise your changes will be lost when your server reboots 1 Naming your server To make your iTrixx server more identifiable on your network enter server name replacing name with your desired server name 2 Setting Time and Date By default your server is configured for GMT To adjust the time zone enter ti...

Страница 6: ...ort When temperature is greater equal to 40 turn relay 1 on when temperature is below 35 the trigger is reset trigger tsensor ge 40 35 relay 1 When accelerometer value is greater than 5 send report when accelerometer is below 1 the trigger is reset trigger shock gt 5 1 report To get a report when digital input 1 is staying on for more than 5 minutes you need to set two triggers trigger din 1 high ...

Отзывы: