Owner’s Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание HANDEL

Страница 1: ...Georg Friedrich HÄNDEL MONO POWER AMPLIFIER ...

Страница 2: ...2 Owner s Manual ...

Страница 3: ...rity and authority not to be found in lesser creations due to the high current capability and operating speed Clever construction techniques enabled us to build an amplifier with high packing density consequently making the signal and power paths extremely short ...

Страница 4: ... your G F HÄNDEL We suggest positioning the unit s so that the speaker connecting cables remain short First establish the AC power connection The IEC mains input is located on the rear panel Make sure that the AC mains switch is set to 0 OFF Connect the power cord to the IEC mains input and plug it into your wall outlet or high quality power strip G F HÄNDEL offers a balanced input because a prope...

Страница 5: ...ost as this is an active output Doing so will short one half of the amplifier and damage may occur Operation With the speakers and the source connected switch the rear mains switch to 1 ON and press the front panel push button to activate the amplifier The blue LED will come on After switching to operating mode the protective circuits take 10s to check all circuits of the power amplifier before en...

Страница 6: ...down the LED will blink until the unit has cooled down sufficiently Likewise if the surveillance circuit detects the presence of DC LED blinks green at the output terminal the amplifier will shut down too Unallowable DC voltages can origin from the source component or the HÄNDEL amplifier itself To isolate the source of the problem disconnect the audio input cable from the HÄNDEL amplifier before ...

Страница 7: ...acement The following work should only be carried out by a qualified technician in accordance to highest electrical safety standards Risk of electric shock Replacing the fuse The fuse must be replaced by a 10AT type 5x20mm Never attempt to short the fuse holder Normally the fuse should never blow if it has it is a sign of a serious fault condition Further investigation is needed ...

Страница 8: ... 400W 2Ω Peak output voltage 94 V pp 33V rms Peak output current 50A continuous 1 10 cycle 20 Hz 20kHz 0 02dB Frequency response 0 400 kHz with filters 0 1 0MHz without filters Damping factor 400 1kHz Signal to noise ratio 98dB linear BW DC 30kHz ref 1W 8Ω Distortion and noise THD N 0 002 20W 1kHz 8 Ω 0 01 200W 20kHz 2 Ω ...

Страница 9: ... unaltered factory serial number must be present on the outside of the unit and must be clearly legible The serial number is an essential part of our conformity declaration and therefore of the approval for operation of the HÄNDEL The serial numbers on the unit and in manual must not be removed or modified and must correspond Furthermore the unit has been found to comply with the limits for a Clas...