background image

PACK 1159/EFGI

MAJIK KONTROL

PRE-AMPLIFIER

OWNER

,

S MANUAL

● 

ENGLISH 

FRANÇAIS 

DEUTSCH 

ITALIANO  

MAJIK KONTROL

majik KONTROL ESDJ SPREAD COVER  3/3/06  4:52 PM  Page 1

Содержание MAJIK KONTROL

Страница 1: ......

Страница 2: ...the apparatus so that its location or position does not interfere with its proper ventilation For example the apparatus should not be situated on a bed sofa rug or similar surface that may block the...

Страница 3: ...dispose of the blown fuse c Fit a new 5 amp BS1362 approved fuse into the carrier and push the carrier back into the plug Always ensure the fuse cover is fitted If the fuse cover is missing do not use...

Страница 4: ...ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no...

Страница 5: ...isher Trade marks used in this publication Linn and the Linn logo are registered trade marks of Linn Products Limited KNEKT INTERSEKT MAJIK and KONTROL are trade marks of Linn Products Limited The con...

Страница 6: ...recording device 5 Connecting to a mains supply 5 Operation 6 Control keys 6 Front panel 6 Handset 7 Standby 10 Basic controls 11 Source selection 11 Volume control 11 Additional controls 12 Balance...

Страница 7: ......

Страница 8: ...ows connection of a phono turntable Even if you do not have a turntable please consider the following points LINE INPUT 6 PHONO can be configured to operate as a moving magnet MM phono stage a moving...

Страница 9: ...the unit where sunlight can shine whether directly diffused or reflected on its display as the infra red IR radiation in sunlight will be picked up by the unit s IR remote sensor and this can adverse...

Страница 10: ...sensor on the display from a KNEKT multi room system etc to an IR Repeater device which controls a third party remote controllable product Rooms 1 4 MAIN RCU The unit can be used as a Line Driver or...

Страница 11: ...hich is fitted with an MC cartridge this is a retailer adjustment See the Important information PHONO input chapter for further details If an earthing lead is fitted to the tonearm cable best results...

Страница 12: ...ng The unit can be connected to any worldwide mains voltage with no adjustment Automatic Voltage Selection AVS is an integral part of the design allowing the power supply to automatically adjust for t...

Страница 13: ...2 6 1 Front panel display location of infra red remote control sensors is indicated Mutes and un mutes the volume Adjust the volume level Headphone socket Accepts a 3 5 mm headphone jack SOURCE Change...

Страница 14: ...access presets Tuner function SCAN To access Scan function Tuner function To navigate setup menus and adjust various features AUDIO ADJUST To play a disc Disc player function To access adjustable audi...

Страница 15: ...c player function MONO is not functional on this product SETUP To enter or exit setup mode HELP Not functional on this product ANGLE AUX auxiliary To select available viewing angles on DVDs AV disc pl...

Страница 16: ...ll operate when one of the keys is pressed CD mode press SHIFT DVD The CD functions will then be assigned as the primary handset keys and the CD LED will operate whenever one of the keys is pressed SH...

Страница 17: ...nded Standby When connected to the mains supply your MAJIK KONTROL will take approximately 8 seconds to configure itself During this time three dots will be shown on the display and the unit will igno...

Страница 18: ...hange the volume setting Press and hold or repeatedly press VOLUME or VOLUME on the front panel Or Press and hold or repeatedly press or on the handset To mute and un mute the volume Press on the hand...

Страница 19: ...ecording sources If the MAJIK KONTROL is being used as a Main room driver in a KNEKT system in the Unit configuration setup menus KNEKT has been set to Main Room the record source must be set to AS KN...

Страница 20: ...or enter to select an option Press to go back to the previous option or menu Press SETUP to exit setup Or Using the front panel Press and hold until the MAIN MENU appears Navigate up or down the opti...

Страница 21: ...and Volume both the currently selected source and the current volume setting will be displayed If set to Volume only the current volume setting will be displayed If set to Source only the current sour...

Страница 22: ...Notes Assigning None as a source type means the input will not be available for selection useful for bypassing unconnected source inputs Not all source types listed are available for direct selection...

Страница 23: ...t the unit s maximum volume For example if you set the volume limit to 60 the volume cannot be adjusted above 60 Allows you to adjust the volume level that the unit will be set to when it comes out of...

Страница 24: ...he Receiver in the Local room of a Linn KNEKT multi room system Please consult Linn or your Linn retailer for details Only applicable if the unit is installed in a Linn KNEKT multi room system Please...

Страница 25: ...ttings can be restored at any time should the unit s setup be changed see below Any alterations to the product s setup that you wish to keep as a new Installation can be stored by selecting this item...

Страница 26: ...300 11 7 5 V peak 5 3 V rms 7 5 V peak 5 3 V rms 7 5 V peak 5 3 V rms Output offset LINE OUT TAPE OUT Headphone Signal to noise ratio LINE INPUTS MM PHONO INPUT MC PHONO INPUT Channel balance Channel...

Страница 27: ...520mm w x 220 mm h x 490 mm d 20 1 4 w x 8 3 4 h x 19 1 4 d 4 90 kg 10 78 lb 6 50 kg 14 33 lb 6 control keys on front panel Remote controllable handset supplied RS232 IN OUT for control via RS232 comp...

Страница 28: ...quiries relating to product servicing should be referred to authorised retailers only Technical support and information For technical support product queries and information please contact either your...

Страница 29: ......

Отзывы: