E1400 V2 Installation Guide
4 Differences between V1 Rev. E/F and V2
The V2 redesign of the E1400 drives resulted in the following changes, that might
be relevant to the customer:
•
The cooling fan is integrated into the drive (on the V1 drives it was an option)
•
The minimum distances between the drives in the cabinet is reduced
•
No double row RJ45 connectors (Ethernet, ME and CMD)
•
X19 (RS232 config connector) is now a dedicated RJ45 connector
•
X33 (STO) is now located on top of the drive and not on the front
•
X20 (Differential analog input) is now on the bottom of the drive and not on
the front
•
The motor brake (X32) is now powered by the 24VDC from X4 (X31, supply
connector for the brake is removed)
Attention:
Configuration can not be directly imported from from a V1 into a V2
drive. It has to be done manually!
If assistance is required contact [email protected].
5 IP Address Selection
The default mode for acquiring an IP address is via DHCP. If no servers respond on
the connected network, the drive switches to the IPv4 Link-Local addressing
scheme (also known as APIPA on Windows systems). This way the drive
automatically assigns itself an address within the range of 169.254.0.1 through
169.254.255.254 (Subnet Mask 255.255.0.0).
Please note that this process can take up to a minute until a valid address is
assigned to the drive.