LinMot Installation Guide
NTI AG / LinMot
®
www.LinMot.com
Page 18/22
10
Regeneration of Power / Regeneration Resistor
There are two possibilities to deal with power regeneration:
Option A:
Connect an additional capacitor to the motor power supply. It is
recommended to use a capacitor >= 10’000 µF
(install capacitor close to the power supply!)
Option B:
Install a regeneration resistor to X1 (RR+ and RR-). The threshold
value of the voltage depends on the used motor voltage power supply.
The max. threshold value must not exceed 88 VDC.
Item
Description
Art. No.
Capacitor
Capacitor 10’000
F / 100 V
0150-3075
Regeneration Resistor
R01-10/60
(10 Ohm, 60 W)
0150-3088
Regeneration Resistor
RR01-10/150 (10 Ohm, 150 W)
0150-3090
11
Ordering Information
Item
Description
Art. No.
E1250-PL-UC
POWERLINK Servo Drive
72VDC/32A
0150-1760
E1250-PN-UC
PROFINET Servo Drive
72VDC/32A
0150-1762
E1250-PD-UC
ProfiDrive Servo Drive
72VDC/32A
0150-2620
E1250-EC-UC
EtherCAT Servo Drive
72VDC/32A
0150-1763
E1250-SE-UC
sercos over EtherCAT Servo Drive
72VDC/32A
0150-1898
E1250-DS-UC
EtherCAT CoE Servo Drive
72VDC/32A
0150-2410
E1250-SC-UC
sercos Servo Drive
72VDC/32A
0150-1764
E1250-IP-UC
ETHERNET IP Servo Drive
72VDC/32A
0150-1761
E1250-LU-UC
LinUDP Servo Drive
72VDC/32A
0150-2493
E1230-DP-UC
PROFIBUS-DP Servo Drive
72VDC/32A
0150-1766
E1200-GP-UC
GENERAL PURPOSE Servo Drive
72VDC/32A
0150-1771
Accessories
Description
Art. No.
Isolated USB-
RS232 converter
Isolated USB RS232 converter with config. cable
0150-2473
Connector for X4
Connector MC 1,5/12-STF-3,5, delivered with drive
0150-3300
RS232 PC config.
Cable 2.5m
For C1100/C1250/E1200/E1400/M8000
0150-2143
Isolated USB-serial
converter
Isolated USB RS232/422/485 converter
0150-3120