C1400 Installation Guide
preliminary
C1400 Series
single axis drive
C1400-CI-
VS-0S
C14X0-XX-
XX-0S
C14X0-XX-
XX-1S
Width
mm (in)
35 (1.38)
43.5 (1.71)
Height
mm (in)
200 (7.87)
235 (9.25)
Depth
mm (in)
153 (6.02)
193 (7.60)
Weight
kg (lb)
Mounting
Backside 2 x M4
Bottom Side 4x M4
Case
IP
20
Storage Temperature
°C
-25…40
Transport Temperature
°C
-25…70
Operating Temperature
°C
0…40
Relative humidity
95% (non-condensing)
Pollution
IEC/EN
60664-1
Pollution degree 2
Site altitude
m amsl
to be defined
Shock resistance (16ms)
-1S option
3.5g
Vibration resistance (10-200Hz)
-1S option
1g
Max. Case Temperature
°C
90
Max. Power Dissipation
W
100
Mounting place
In the control cabinet
Mounting position
vertical
Distance between drives
mm (in)
≥ 200 (8) top / bottom
Drives with fan can be mounted vertically
side by side