3.1. Power Wiring
The
Link IP iDP
can be supplied in 2 different ways :
•
PoE (802.3at Class 3)
•
External power supply 12V DC
3.2. Relais : Mode and wiring
The relay has two different mode depending on the configuration «
JP1
» jumper (see description of components):
•
« 12V Output »
mode (
default setting
): At rest, the doorphone sends 12V to the "
NC
" and "
COM
" relay
terminals. When opening the door, the doorphone sends 12V between "
NO
" and "
COM
" relay terminals.
Jumper "JP1" must be placed between 2 and 3 terminals :
The maximum consumption supported is 12V / 500mA.
Wirind in « 12V Output » mode :
•
« Relay» mode
: At rest, the "
NC
" and "
COM
" relay terminals are short-circuited. When opening the door,
the "
NO
" and "
COM
" terminals are short-circuited.
The 2 jumpers are positioned between terminals 1 and 2, then 3 and 4. (default):
Wiring in « Relais » mode :
JP1
The 2 jumpers are placed
1
2
3
4
JP1
« Relais » mode, only one
jumper is placed on 2 and
3
1
2
3
4