background image

 

Linkcom France 

11 rue du Soleil Levant 92140 CLAMART                                                                                     Copyright © 2008 – Linkcom – Tous droit réservés 

6.2 Incoming calls trunk route configuration in P2P mode 

When the Link gate SIP should be set to P2P mode, it is important to set the translation table for incoming phone 
calls to match phone subscriber extension’s numbers with IP addresses. 
 After making changes use the save changes button. 
 

 

 

 

 

 

 

 

 

 

 

6.3. Outgoing call configuration: 

By default there is no call restriction programmed in the (LCR) table. The Link Gate SIP accepts all SIP calls through 
its trunk interfaces « IP 1adress » and « IP 2adress ». Calls will be rooted sequentially over modules GSM 1 et 2.  

Set up IPBX External call trunk route parameters (trunk SIP or Outbound proxy sip), SIP phone or soft phone to 
make calls through the Link Gate SIP. The only parameters that should be configured are IP 1 and 2 addresses and 
port SIP, 5060 (there is no SIP authentification in mode P2P). 

 

7. SIP Server mode Configuration 

To parameter the Link gate SIP in SIP server mode, refer to paragraph 2: “Setting operational mode” 
In SIP Server mode « Number translation » menu is not used 
 Two new menus are available: « SIP Parameters » and « SIP Server » 
 
In SIP mode Server the Link Gate SIP can be parameter in 2 ways: 

 

SIP server (internal) : The Link Gate SIP work in this case in stand alone it allow recording up to 10 SIP 

phone. The Link Gate SIP in this case behaves as an IPBX.  

 

SIP server (external) : The Link Gate SIP is connected and registered to an IPBX as a SIP phone. For each 

GSM Module one SIP account should be created on the IPBX to allow receiving external calls. Outgoing calls 
through the GSM channels are made by adding 2 trunks SIP through IP 1 and IP 2 of the Link Gate SIP. 

7.1. SIP server mode (internal) 

Set the Link Gate SIP in MENU SIP SERVER tick the Blanc Box to Enable SIP server mode 
Give then the Name of the SIP server« realm » 
Enter the outgoing call prefix to access individually each channel. 
You are able then to register up to 10 SIP accounts for your SIP phone. 
Complete the number of each SIP phone extension ( this number will same as user SIP name in Password). 
After making changes use button save and restart
 

 

Set a number and IP 
adress, whitch is set 
on a desired phone. 

Содержание Link Gate SIP

Страница 1: ...Linkcom France 11 rue du Soleil Levant 92140 CLAMART Copyright 2008 Linkcom Tous droit r serv s 1 Link Gate SIP Firmware version 1 20 User guide v1 0...

Страница 2: ...Linkcom France 11 rue du Soleil Levant 92140 CLAMART Copyright 2008 Linkcom Tous droit r serv s 2 Content...

Страница 3: ...k outgoing call restriction to GSM network Priority connection through either the 1st or the 2nd GSM module LCR Smart Call back automatic incoming calls routing up CLIP Direct access assign of IP addr...

Страница 4: ...F SIP Server mode 4 not used 3 Putting into Service 3 1 Module Description SIM cards position Before inserting the SIM card check the status of PIN code in a mobile phone starting with PIN or without...

Страница 5: ...2 168 1 250 255 255 0 0 In your web browser enter IP address of Link gate SIP defaults setting are 192 168 1 250 user is admin and password is 1234 Red LED indicating channels Error status LED is off...

Страница 6: ...hose steps 4 3 Manual configuration IP SIP mode If you prefer to enter manually the IP addresses make sure to fill out all IP addresses Network mask Default Gateway and then all DNS parameters 4 4 Aut...

Страница 7: ...ng calls trunk route refer to menu GSM Gate 6 1 Incoming calls trunk route configuration GSM trunk route settings can be made in the section GSM Gate module 1 and GSM Gate module 2 It is important to...

Страница 8: ...ode refer to paragraph 2 Setting operational mode In SIP Server mode Number translation menu is not used Two new menus are available SIP Parameters and SIP Server In SIP mode Server the Link Gate SIP...

Страница 9: ...X SIP Port Name IPBX extension SIP user name Password IPBX extension SIP user name password Press then Save changes to save the parameters The Link Gate SIP will inform you with a message Failed Savin...

Страница 10: ...of 16 seconds inviting callers to dial the subscriber s number they want to reach This message can be recorded through a PC using the special supplied RS 232 interface and the recording software OGMre...

Страница 11: ...cribed number When called party call back the call is automatically routed to extension which made the call When connection was successful data are erased from memory 0 It adds automatically 0 before...

Страница 12: ...d with Antenna position o 113 to 99 dBm very bad signal it is impossible to use any GSM network services o 98 to 83 dBm bad signal you can send SMS messages Since level 87dBm you can establish voice c...

Страница 13: ...m Tous droit r serv s 13 8 4 Setting Audio Choose the audio codecs priority for SIP calls There codecs are available G711u G711a G726 GSM 8 5 Service Firmware version Event log enhanced or basic log D...