LK-CP63X SERIES CONTROL PANEL 

Feature 

The controller consists of a built-in switching power supply, a main control board,
a driver board and a connecting board

Single Channel, dual Channel, 5 Channel and cascade controls

Power indicator/reset, Open/Stop/Close & channel selection buttons with backlight

Can handle external input signals  of  Manual Switch, Remote Control, Timer
Smoke/Gas/Wind & Rain /Temperature & Humidity Sensors

Output fire feedback signal to fire centre

Switching power supply 10A/15A/20A/25A optional

Specification 

Input 

Voltage 

Output 

Voltage 

Output 

Current 

Working 

Frequency 

Receiving 

Sensitivity 

Working 

Temperature 

Dimension 

AC120V 

AC230V 

DC12V 

DC24V 

10-25A  433.92 MHz 

-100 dBm 

-20

  +65

  272*228*73mm 

Button & Dimension 

Led/Key 

Color 

Status 

Function 

L1/K1 

Blue 

On/Off 

AC power indicator, Reset 

L2/K2 

Green 

On/Off /Flash 

Open 

L3/K3 

Red 

On/Off/Flash 

Stop 

L4/K4 

Yellow 

On/Off/Flash 

Close 

L5/K5

L9/K9 

Blue 

On/Off/Flash 

Channel 1

Channel 5 

Содержание LK-CP63X Series

Страница 1: ... Smoke Gas Wind Rain Temperature Humidity Sensors Output fire feedback signal to fire centre Switching power supply 10A 15A 20A 25A optional Specification Input Voltage Output Voltage Output Current Working Frequency Receiving Sensitivity Working Temperature Dimension AC120V AC230V DC12V DC24V 10 25A 433 92 MHz 100 dBm 20 65 272 228 73mm Button Dimension Led Key Color Status Function L1 K1 Blue On...

Страница 2: ...D WRD Wind Rain sensor down SU Slave control up T Temp sensor signal SD Slave control down H Humidity sensor signal FC1 Fire center feedback1 TU Timer up FC2 Fire center feedback2 TD Timer down FS Fire signal input Switch Switch Optional Function S1 0 Passive Smoke Gas sensor 1 Active Smoke Gas sensor S2 0 Passive Wind Rain sensor 1 Active Wind Rain sensor S3 0 Passive T H sensor 1 Active T H sens...

Страница 3: ...r Reset and Shielding After manual signal processed controller resets receives input signals in real time After processing the signals from fire centre smoke sensor or gas detector the controller immediately shields all the input signals the controller must be reset by pressing K1 manually After opening the window returns feedback signal After wired W R sensor signal processed the controller shiel...

Страница 4: ... a master controller a slave controller or play a dual role of master slave controller at the same time As a master controller connects to the motors or slave controllers to drive them As a slave controller input terminals SU and SD are connected to the output terminals M and M of the master controller to receive the instructions to drive motors or drive the motors independently Play a dual role o...

Отзывы: