Please read the following instruc ons carefully before installing this product

Installing this product must comply with the effec ve local electricity specifica ons 

The control system must be installed by the professional 

The main power must be cut off before wiring to ensure safe opera on

Addi ve maximum output power of each single channel of double channel controller 
MUST NOT exceed the total rated power of the controller

Addi ve maximum output power of each single channel of 5 channel controller MUST 
NOT exceed the total rated power of the controller, and the maximum output current of 
each channel MUST NOT exceed 10A

Do not use metal objects to touch or cover the controller, otherwise it will affect the 
remote control signal recep on

The maximum transmission distance of the wireless signal can reach 50 meters or more 
in the open condi on

The distance between the controller and ground should be more than 1.5 meters

The distance between the controller and ceiling should be more than 0.3 meters

The distance between the controller and motor should be more than 1.5 meters

Avoid sta c interference and prevent sta c damage to electronic components

Please use the so  wire and cable, a er installa on ensure that the cable carrier is not 
affected by the longitudinal tension

An external sensor must use a product that is compa ble with this controller

Non-professionals is not allowed to disassemble the controller. If any func on is 
abnormal, please contact your local dealer

.

¢

Installa on instruc on

No.

Symptom

Solu on

1

LED flashes, receiver shut down

1. Check the connec on of wires
2. Check the receiver se ng

2

LED on the transmi er is off or weak

1. Make sure the right installa on of the ba ery
2. Change the ba ery

3

The transmi er and the receiver work well,
the motor does not work

1. Check the wiring of motor
2. Make sure the motor no failure

¢

Stroke memory

The controller can set and memorize the opening stroke. Upon the stroke set, the 
window opening signal is triggered once, the motor will run the memorized stroke one 

me

The default memorized stroke runs for 5 minutes

Press both of UP /DOWN bu ons on the controller for 3 seconds, LEDs flash 3  mes and 
off, successfully entered the stroke memory se ng state

In the stroke memory se ng state, the manual keys are forced to the con nued-run 
mode, the remote control keys are forced to the inching mode

Select the channel(S) to be set, the default is all selected, all the channel indicators light. 
Press the channel selec on key(s), the indicators light, press the channel selec on key(s) 
again the indicator is off, it is deselected. The se ng is invalid without opera on in 15 
seconds

A er the channel selected, determine the stroke that needs to be memorized by pressing 
the manual key or the remote control key by moving or jogging

The memorized stroke can be set to one channel or any combina on of channel

A er the memorized strokes determined, turn on all the channel indicators for se ng the 
memorized stroke. Press both of UP /DOWN bu ons on the controller for 3 seconds, LEDs 
flash 5  mes and off, the memorized strokes of all channels set successfully and exit the 
stroke memory se ng state, manual bu ons and remote control bu ons restored to the 
original mode

In stroke memory se ng state, no opera on is performed within 15 seconds, LEDs flash 3 

mes slowly and off, the stroke memory se ng state is automa cally exited, and the last 

memorized stroke is retained

Stroke memory can be set repeatedly. The controller only retains the last successful 
stroke value and automa cally clears the previous one

In stroke memory se ng state, press both of STOP /DOWN bu ons on the controller for 
3 seconds LEDs flash 3  mes the memorized stroke is deleted and restored to the default 
output for 5 minutes

When the memorized strokes of master controller and slave controller are not the same, 
the master controller will run its own memorized stroke. The slave controller will run the 
shorter stroke when it receives the cascade signal from the master controller

The memorized stroke set for each channel is retained in case the controller is powered 
down or reset

When closing the window, the output  me is 5 minutes