Страница 2: ...L AC live wire FSO Fire signal output N AC null wire FOO Fire output NO E AC earth wire FOC Fire output NC 24V 24VDC input posi ve 24V 24VDC output 24V 24VDC input nega ve FSI Fire signal input M 24VDC motor posi ve COM Sensor COM M 24VDC motor nega ve S Slave control up MU Manual switch up S Slave control down MS Manual switch stop 12V DC12V output MD Manual switch down WRD Rain sensor down MG Ma...
Страница 3: ...as group control status Press UP bu on the windows open LED turns on turns off a er 5 seconds Press DOWN bu on the windows close LED turns on turns off a er 5 seconds Press STOP bu on the motors stop LED turns on LED turns off a er 1 second Channel control Press channel selec on keys the corresponding LED lights channel selected Press the channel selec on bu on again or no opera on on controller thin...
Страница 4: ......
Страница 5: ...Upon the stroke set the window opening signal is triggered once the motor will run the memorized stroke one me The default memorized stroke runs for 5 minutes Press both of UP DOWN bu ons on the controller for 3 seconds LEDs flash 3 mes and off successfully entered the stroke memory se ng state In the stroke memory se ng state the manual keys are forced to the con nued run mode the remote control ke...