background image

  

 

27 

MERCURY72-xxxM Series 

Electrical Characteristics (at STC)

 

Max Power (Pmax) 

380/385/390/395/400/405 

Power Tolerance 

±3% 

Max

.

 Power

 Voltage (Vmp) 

40.25/40.55/40.85/41.20/41.50/41.80 

Max

.

 Power

 Current (Imp) 

9.44/9.49/9.55/9.59/9.64/9.69 

Open Circuit Voltage (Voc) 

±

3

 

48.90/49.30/49.70/50.10/50.45/50.85 

Short Circuit Current (Isc) 

±

4

 

10.00/10.05/10.10/10.15/10.20/10.25 

 

 

 

 

 

 

 

 

 

 

 

Mechanical Specifications 

External Dimensions 

 

2008x 1002 x 40 mm 

 

Weight 

 

22.5kg 

 

 

Solar Cells 

 

Monocrystalline 158.75 x 158.75mm 
(72 Cells-9BB) 

 

Front glass 

 

3.2 mm tempered glass, low iron 

 

Frame 

Anodized Aluminium 6063 Alloy 

 

Junction Box 

 

IP68 

 

Diode 

 

3 Diodes GF3045MG 

 

Output Cables 

 

4.0 mm2, symmetrical lengths 1000mm 

 

Connector 

 

Ningbo Shihe New Energy Technology 
DJ2011-4 (Rated 1500V) 

Maximum 

mechanical Load 

 

3600Pa 

 

Hailstone Impact Test 

 

80 km/h for 25mm ice ball 

 

Working Conditions 

 

Pmax Temperature Coefficient 

 

-0.42 %/°C 

 

Voc Temperature Coefficient 

 

-0.32 %/°C 

 

Isc Temperature Coefficient 

 

+0.04 %/°C 

 

Operating Temperature 

 

-40~+85 °C 

Nominal Operating Cell Temperature 

(NOCT) 

 

45±2 °C 

 

Maximum System Voltage 

 

1500V( TÜV ) 

 

Maximum Series Fuse 

 

15A 

 

Static loading 

 

3600Pa 

 

Grounding conductivity 

 

<0.1Ω

 

 

Application Class 

 

Class A 

 

Insulation Resistance 

 

100M

Ω

 

Содержание Jupiter Series

Страница 1: ...Installation Guide for Link Energy Photovoltaic Module Ver 1st May 2020 For PILOT JUPITER and MERCURY Series ...

Страница 2: ...No 4 3 Mechanical Installation No 5 3 1 Selecting the location No 5 3 2 General installation No 5 3 3 Installation method No 7 3 4 Module Mounting Guidelines No 8 4 Electrical Installation No 10 4 1 General installation No 10 4 2 Earthing and Grounding No 11 4 3 Fusing No 12 4 4 Inverter Selection and Compatibility No 12 5 Maintenance No 13 6 Dimensions Parameters No 14 ...

Страница 3: ... may be used in system operating at more than 50V DC or 240W where general contact access is anticipated Modules qualified for safety under IEC 61730 2 and within this application class are considered to meet the requirements for Safety Class II Installing solar photovoltaic systems requires specialized skills and knowledge Installation should only be performed by qualified persons Installers shou...

Страница 4: ...d nameplates or components from the modules Do not apply paint or adhesive to the module top surface To avoid damage to the backsheet do not scratch or hit the backsheet Do not drill holes in the frame This may compromise the frame strength and cause corrosion of the frame Do not scratch the anodized coating of the frame except for grounding connection It may cause corrosion of the frame or compro...

Страница 5: ...event their degradation Keep children well away from the system while transporting and installing mechanical and electrical components Artificially concentrated sunlight shall not be directed on the module or panel And completely cover the module with an opaque material during installation to prevent electricity from being generated Do not wear metallic rings watchbands ear nose lip rings or other...

Страница 6: ... local authority Do not use panels near equipment or in places where flammable gases may be generated The modules have been rated Fire Class C 2 Product Identification Each module has two labels providing the following information 1 Nameplate describes the product type rated power rated current rated voltage open circuit voltage short circuit current all as measured under standard test conditions ...

Страница 7: ...ator The module should not be shaded at any time Do not use modules near equipment or in locations where flammable gases may be generated or collected 3 2 General Installation The module mounting structure must be made of durable corrosion resistant and UV resistant material In regions with heavy snowfall in winter select the height of the mounting system so that the lowest edge of the module is n...

Страница 8: ...stalling a module on a pole choose a pole and module mounting structure that will withstand the anticipated winds for the area Dust building up on the surface of the module can impair with module performance We recommend installing the modules with a tilt angle of at least 10 degrees making it easier for dust to be washed off by rain Observe the linear thermal expansion of the module frames the re...

Страница 9: ...ng Guideline Failure to comply may result in damage to modules or detached from the mounting system voiding the warranty Module can be installed in both landscape and portrait modes For best performance separate laying of positive and negative cables wherever possible Induced voltage surges in the DC main cable should be minimized by laying the positive and negative cables as close together as pos...

Страница 10: ...8 3 4 Module Mounting Guideline See below for reference ...

Страница 11: ...gure 2 PV module installed at long side with Clamp fitting method Figure 3 Clamp Dimension mm mm The module clamps must not come into contact with the front glass or deform the frame in any way Avoid shading effects from the module clamps and insertion systems ...

Страница 12: ...hardware used must be compatible with the mounting structure material to avoid galvanic corrosion It is not recommended to use modules with different configurations grounding wiring in the same system The module maximum system voltage is 1000V DC or 1500V DC For applications requiring a high operating voltage several modules can be connected in series to form a string of modules The system voltage...

Страница 13: ...ameter that been used for wiring must reach at least 4 mm2 The DC current generated by photovoltaic systems can be converted into AC and fed into a public grid As local utilities policies on connecting renewable energy systems to their grids vary from region to region A qualified system designer or integrator should always be consulted Building permits inspections and approvals by the local utilit...

Страница 14: ...e can withstand when one string is shaded then the other parallel strings of modules will be loaded by the shaded string and current will flow and therefore impacts the number of strings in parallel 4 4 Inverter Selection and Compatibility Link Energy modules normally can be operated together with either galvanically isolated with transformer and transformer less inverters Potential Induced Degrad...

Страница 15: ...nsmission of sunlight partly or fully of the module b Modules covered partly by dirt or objects will increase the risk of development hotspot on the solar cell causing performance drop which is excluded from the warranty c Always use clean water and a soft sponge or cloth for cleaning A mild non abrasive cleaning agent may be used to remove stubborn dirt d Check the electrical grounding and mechan...

Страница 16: ...e 156 75 x 156 75 mm 36pcs Front glass 3 2 mm tempered glass low iron Frame Anodized Aluminium 6063 Alloy Junction Box IP68 Diode THY2550 SDA2040 Output Cables 4 0 mm2 symmetrical lengths 900mm Connector MC4 Compatible Maximum mechanical Load 5400Pa Hailstone Impact Test 80 km h for 25mm ice ball Working Conditions Pmax Temperature Coefficient 0 42 C Voc Temperature Coefficient 0 32 C Isc Temperat...

Страница 17: ...48pcs Front glass 3 2 mm tempered glass low iron Frame Anodized Aluminium 6063 Alloy Junction Box IP68 Diode CD PV3045 GF3045MG Output Cables 4 0 mm2 symmetrical lengths 900mm Connector MC4 Compatible Maximum mechanical Load 3600Pa Hailstone Impact Test 80 km h for 25mm ice ball Working Conditions Pmax Temperature Coefficient 0 42 C Voc Temperature Coefficient 0 32 C Isc Temperature Coefficient 0 ...

Страница 18: ...ing Temperature 40 85 C Nominal Operating Cell Temperature NOCT 45 2 C Maximum System Voltage 1500V TÜV Maximum Series Fuse 15A Static loading 3600Pa Grounding conductivity 0 1Ω Application Class Class A Insulation Resistance 100MΩ Mechanical Specifications External Dimensions 1480x 992 x 40 mm Weight 16 5kg Solar Cells Polycrystalline 156 75 x 156 75 mm 54pcs Front glass 3 2 mm tempered glass low...

Страница 19: ...rature Coefficient 0 04 C Operating Temperature 40 85 C Nominal Operating Cell Temperature NOCT 45 2 C Maximum System Voltage 1500V TÜV Maximum Series Fuse 15A Static loading 3600Pa Grounding conductivity 0 1Ω Application Class Class A Insulation Resistance 100MΩ Mechanical Specifications External Dimensions 1650x 992 x 40 mm Weight 18 5 kg Solar Cells Polycrystalline 156 x 156 mm 60pcs Front glas...

Страница 20: ...ture Coefficient 0 04 C Operating Temperature 40 85 C Nominal Operating Cell Temperature NOCT 45 2 C Maximum System Voltage 1500V TÜV Maximum Series Fuse 15A Static loading 3600Pa Grounding conductivity 0 1Ω Application Class Class A Insulation Resistance 100MΩ Mechanical Specifications External Dimensions 1956x 992 x 40 mm Weight 21 kg Solar Cells Polycrystalline 156 75 x 156 75 mm 72pcs Front gl...

Страница 21: ...Temperature Coefficient 0 04 C Operating Temperature 40 85 C Nominal Operating Cell Temperature NOCT 45 2 C Maximum System Voltage 1000V TÜV Maximum Series Fuse 15A Static loading 5400Pa Grounding conductivity 0 1Ω Application Class Class A Insulation Resistance 100MΩ Mechanical Specifications External Dimensions 1480x 670 x 40 mm Weight 11 kg Solar Cells Monocrystalline 156 75 x 156 75 mm 36pcs F...

Страница 22: ...sc Temperature Coefficient 0 04 C Operating Temperature 40 85 C Nominal Operating Cell Temperature NOCT 45 2 C Maximum System Voltage 1500V TÜV Maximum Series Fuse 15A Static loading 3600Pa Grounding conductivity 0 1Ω Application Class Class A Insulation Resistance 100MΩ Mechanical Specifications External Dimensions 1320x 992 x 35 40 mm Weight 14 8 kg Solar Cells Monocrystalline 156 75 x 156 75 mm...

Страница 23: ...ent 0 32 C Isc Temperature Coefficient 0 04 C Operating Temperature 40 85 C Nominal Operating Cell Temperature NOCT 45 2 C Maximum System Voltage 1500V TÜV Maximum Series Fuse 15A Static loading 3600Pa Grounding conductivity 0 1Ω Application Class Class A Insulation Resistance 100MΩ Mechanical Specifications External Dimensions 1480x 992 x 40 mm Weight 16 5 kg Solar Cells Monocrystalline 156 75 x ...

Страница 24: ...icient 0 32 C Isc Temperature Coefficient 0 04 C Operating Temperature 40 85 C Nominal Operating Cell Temperature NOCT 45 2 C Maximum System Voltage 1500V TÜV Maximum Series Fuse 15A Static loading 3600Pa Grounding conductivity 0 1Ω Application Class Class A Insulation Resistance 100MΩ Mechanical Specifications External Dimensions 1650x 992 x 35 40 mm Weight 17 5 18 5kg Solar Cells Monocrystalline...

Страница 25: ...t 0 42 C Voc Temperature Coefficient 0 32 C Isc Temperature Coefficient 0 04 C Operating Temperature 40 85 C Nominal Operating Cell Temperature NOCT 45 2 C Maximum System Voltage 1500V TÜV Maximum Series Fuse 15A Static loading 3600Pa Grounding conductivity 0 1Ω Application Class Class A Insulation Resistance 100MΩ Mechanical Specifications External Dimensions 1979x 1002 x 40 mm Weight 22 5 kg Sol...

Страница 26: ...t Cells 9BB Front glass 3 2 mm tempered glass low iron Frame Anodized Aluminium 6063 Alloy Junction Box IP68 Diode 3 Diodes 30SQ045 Output Cables 4 0 mm2 symmetrical lengths 1200mm Connector Ningbo Shihe New Energy Technology DJ2011 4 Rated 1500V Maximum mechanical Load 3600Pa Hailstone Impact Test 80 km h for 25mm ice ball Working Conditions Pmax Temperature Coefficient 0 42 C Voc Temperature Coe...

Страница 27: ...8 75mm 132 Split Cells 9BB Front glass 3 2 mm tempered glass low iron Frame Anodized Aluminium 6063 Alloy Junction Box IP68 Diode 3 Diodes 30SQ045 Output Cables 4 0 mm2 symmetrical lengths 1200mm Connector Ningbo Shihe New Energy Technology DJ2011 4 Rated 1500V Maximum mechanical Load 3600Pa Hailstone Impact Test 80 km h for 25mm ice ball Working Conditions Pmax Temperature Coefficient 0 42 C Voc ...

Страница 28: ...it Cells 9BB Front glass 3 2 mm tempered glass low iron Frame Anodized Aluminium 6063 Alloy Junction Box IP68 Diode 3 Diodes 30SQ045 Output Cables 4 0 mm2 symmetrical lengths 1000mm Connector Ningbo Shihe New Energy Technology DJ2011 4 Rated 1500V Maximum mechanical Load 3600Pa Hailstone Impact Test 80 km h for 25mm ice ball Working Conditions Pmax Temperature Coefficient 0 42 C Voc Temperature Co...

Страница 29: ...lls 9BB Front glass 3 2 mm tempered glass low iron Frame Anodized Aluminium 6063 Alloy Junction Box IP68 Diode 3 Diodes GF3045MG Output Cables 4 0 mm2 symmetrical lengths 1000mm Connector Ningbo Shihe New Energy Technology DJ2011 4 Rated 1500V Maximum mechanical Load 3600Pa Hailstone Impact Test 80 km h for 25mm ice ball Working Conditions Pmax Temperature Coefficient 0 42 C Voc Temperature Coeffi...

Страница 30: ...Cells 9BB Front glass 3 2 mm tempered glass low iron Frame Anodized Aluminium 6063 Alloy Junction Box IP68 Diode 3 Diodes GF3045MG Output Cables 4 0 mm2 symmetrical lengths 1000mm Connector Ningbo Shihe New Energy Technology DJ2011 4 Rated 1500V Maximum mechanical Load 3600Pa Hailstone Impact Test 80 km h for 25mm ice ball Working Conditions Pmax Temperature Coefficient 0 42 C Voc Temperature Coef...

Отзывы: