background image

 

 

 

3-5 

Err

 = Will open the Error Logs Screen where you can see the number of error situations encountered. 

See the next section for details on error codes. 

ECS

 =Will display the version of software in the ECS+ Control Box 

SOF

 = will display the version of firmware in the Handset 

rES

 = will place the system in Reset Mode, requiring the table to be fully lowered prior to resuming 

normal operation. 

SL

 = This function has been removed. 

SU

 = This function has been removed. 

CAL

 = Allows the user to enter the actual height of the table top. The system will default to a generic 

number if this is not set. Use up       and down       arrow buttons to adjust displayed height to match 

measured height. 

Un

 = Units function allows the user to select metric or imperial units by pressing the up       or down 

arrow buttons. (Settings Menu.) 

Exit 

To enter a menu press up and down simultaneously. 

To adjust a value once inside a menu press up or down. 

To save and exit a menu press up and down simultaneously

 

 
Error Log Details 

The Err option will display the Error Logs Screen where you are able to see the number of error 

situations encountered. Use the up       and down       buttons to scroll through the codes. 

LOH

 = Log Over Heat - a motor has been overheated this number of times. 

COH

 = Card Over Heat - the ECS+ box has been overheated this number of times. 

Tot

 = Total adjusted distance. 

The error counter is stored in the ECS+ box, not the handset so it is not important that the original 

handset is used to review errors. 

 

Error Codes 

1. Hard Stop 

2. Back off 

3. Soft stop 

Содержание 4-MEM ECS Plus

Страница 1: ...OL ECS controlled systems only Mount the Handset Use the 2 attached screws for fixing the handset to the table top If the thickness of the table top is less than 18mm please use shorter screws Connect the Handset Connect the handset to the Handset port of the ECS box Handset Layout Display Layout Menu mode Imperial inch M Memory Thermometer E Error codes Metric centimeter Reset ...

Страница 2: ... the system to calibrate display will go blank The table is now ready for use Under normal conditions the display automatically shows the layout as below This may take 2 to 5 seconds If the display continues to show three dashes the table is still in Reset mode In that case press the down button until the table is at the lowest position Settings By pressing the up and down buttons Simultaneously y...

Страница 3: ... measured height Un Units function allows the user to select metric or imperial units by pressing the up or down arrow buttons Settings Menu Exit To enter a menu press up and down simultaneously To adjust a value once inside a menu press up or down To save and exit a menu press up and down simultaneously Error Log Details The Err option will display the Error Logs Screen where you are able to see ...

Страница 4: ...al measured height by using the up and down arrow buttons Setting Memory Buttons To set the memory buttons use the up and down arrow to navigate to the desired height Rapidly press and release the up and down arrow buttons simultaneously three times The letter S will display on the screen Press and release the memory button you ve chosen for the current height and the display will change to S1 S2 ...

Страница 5: ...own buttons simultaneously to enter the Settmgs Menu Press up button until you reach rES To enter press up and down buttons simultaneously Press the down button and hold until the columns have reached the lowest position ...