background image

AQUILINE Foot Operated Switch 

WIRING 
===================================================================================

 

1.  

 

WARNING:  TO AVOID PERSONAL INJURY, DO NOT USE THIS SWITCH ON MACHINERY WITH AN 

UNGUARDED POINT OF OPERATION. 

    

 

READ WARNING STATEMENT

 on reverse side of this page.

 

2.  When wiring up this device make sure 

POWER IS OFF AND LINES ARE DEAD.

 

3.  MAXIMUM FUSE RATING:  Amperage and voltage not to exceed nameplate rating – Quick Acting. 
4.  Supply cord with flexible conductors (leads) to be prepared as shown. (See Diagram “A”). 
     Supply cord with prepared flexible conductors.  Use special purpose crimping tools to apply female quick connect and when required, ring 
     terminals to conductors. 

 NOTE:

 For metal Aquiline models, the cord must include a 4-1/2 in. (114mm) long green or for CE Marked foot switches, a green / yellow 

 

colored grounding conductor. Apply a #8 (4.4mm ø) ring type terminal. Attach to and tighten the protective earthing (grounding terminal with 

 lockwasher) screw 11-16 in.-lbs. (1.2 to 1.8 Nm). 

 NOTE:

 For CE Marked foot switches, a cord guard or bend relief must be provided that extends beyond the cord clamp at least five times the 

 

overall diameter of the flexible cord. 

Use 2 conductor cord for single pole 
normally open or normally closed 
operation. Use 3 conductor cord for 
single pole double throw operation. 
Maximum flexible conductor size: #14 
AWG. (1.5 mm

2

 ).

 

3/16 IN x 0.031 or x 0.020 
(4.8 x 0.8 or x 0.5 MM) 
 Female quick-connect terminal. 
See switch for thickness 
 of Male terminal. 

Cord Clamp

2-1/8 in (53.9

 

mm)

 

3/8 IN (9.5

 mm) Min. 

Base 

Make sure cover is pried off 
of base from this side only. 

 

5.  Remove cover from base by prying the cover with a flat blade screwdriver on the side shown in Diagram “B”. 
     

NOTE:

 For metal Aquiline models, remove hinge screws. 

6.  Loosen or remove cord clamp screws, insert cord and connect inner conductors (leads) of cord to appropriate switch terminals. 
     (See Diagram “C”).  

NOTE:

  For metal Aquiline models, remove plastic insulation from switch before connecting cord leads to terminals.

 

3/16 IN. x 0.031 or x 0.020
(4,8 x 0,8 or 0,5 mm)
flat quick-connect tabs
for switch terminations.

Tighten cord clamp screws
Alternately 12 to 14 IN-LBS.
 (1,4 to 1,5 Nm).

Cord clamp accepts cord,
sizes .250 to .435 diameter.
(6 to 11 mm).

1st Stage

2nd Stage

See note 6

This interior switch only has
Solder type terminations

  

IMPORTANT!     

Make sure that the

hinge hole in the cover is located
over this hinge tab pins prior to
snapping the cover onto the base.

 

7.  The circuit designations shown in Diagram "C" are at assembly.  For 974-S only, the left side interior switch is reverse actuated in the foot 
     switch housing.  For example, the normally closed terminal (NC) marking molded into the switch body will provide a normally open circuit when 
     the interior switch is assembled in the foot switch housing.

 

8.  Re- assemble cover to base by snapping onto hinge tabs as shown in Diagram "D".   
     

NOTE:

 For metal Aquiline models; replace plastic insulation on switch then reassemble cover with hinge screws.

 

9.  

CLEANLINESS

 must be observed during installation and in use.

 

     

on a 

REGULAR BASIS,

 inspect foot switch frequently to guard against wear, damage, unlawful alterations or removal of guards, or for   

     unusual enclosure deterioration and the like.  Inspect the entire length of the connecting cord (or wiring system) from where it enters the foot   
     switch to the equipment it’s wired up to for wear, loose strain relief connections and the like. 

DO NOT OPERATE

 the foot switch if any of the  

     above is observed or if the nameplate or warning label has been obscured or removed.

 

 It is 

IMPERATIVE

 that inspection authorities and users exercise more than ordinary care with regard to installation and maintenance and that 

 this information be made available to the end user, operators, maintenance personnel and to others responsible for the proper installation and 
 safe operation of this foot switch.

 

 ADDITIONAL COPIES

 of this information sheet and warning labels are available upon request

.

 

MOUNTING 
================================================================================ 

1.  Aquiline foot operated switches are furnished with a non-skid base pad and can be mounted with the base pad attached.

 

2.  Use 2 number 4 thread-cutting (self-tapping) screws and two number 4 lock washers when mounting foot switch to full guard. 

(See Diagram "E")  For metal Aquiline models, remove 2 number 4 baseplate screws and use for mounting along with two number 4                  
lock washer. Also, place two number 6 lock washer, furnished with guard, between the bottom of the metal Aquiline baseplate inside of guard                          
and check for continuity between the foot switch enclosure grounding lead and guard. 

      

 

 

#4 Flat head thread-cutting screw 

#522-B 14 Full guard with 
assem bly hardware and 
instructions available upon 
request. 

#4 Lockwasher

N ote: 
For tw in models use #522-B12 full guard. 

  

Form 997-J Rev L

 

DIAGRAM “E”

DIAGRAM “C”

DIAGRAM “D”

 

DIAGRAM “A”  

DIAGRAM “B”  

974-S (DPDT) 

972-S (2  STAGE) 

971-S (SPDT) 

Отзывы: