01
23
01 23
-29-
5.3 Sweep
Touch [Sweep setting] and set each parameter.
■Sweep size
:
Select data size to sweep from 8
or 16bits.
For 16bits, select the endian
from big or little.
e.g) Set “0123h”
Little endian Big endian
■Position
Set the position of data field where sweep data is going to be inserted from
0
~
7 for CAN, 0
~
63 for CAN FD, 0
~
7 for LIN
e.g.
)
Size: 16bit, Position: 2
Two data in grey color is inserted. Other data are the one set on “Data”field.
■Sweep value
On the first box, input the initial
value in decimal.
On the second box, input first
target value and time (ms).
On the third box, input the
second target value and time
(ms).
On the fourth box, input the third target value and time (ms).
Press [±] to change positive/negative value. To input the negative value,
input value in complement notation of 2.
In the example of setting, it increases 100 after 1 second and decreases
-127 after 2 seconds, and increase 100 after 0.5 second.
Mark on the box of “Loop” to repeat the sweep.
When the sweep size is 8 bits, the lower 8 bits are used.