background image

CONTENTS

PRODUCT DESCRIPTION

The PERS-2400B Console is a supervised wireless emergency reporting product designed 
for medical alert applications. The table-top or wall-mount Console provides “pushbutton” 
emergency assistance to anyone who desires additional security and peace of mind. For 
the visually impaired, each button on the Console is molded with braille characters to 
identify the button’s function.

 

The Console receives signals from up to 16 Linear wireless transmitters. Activating a 
transmitter causes the Console’s digital communicator to send the appropriate alarm report 
to the central monitoring station via the standard telephone network. In addition to the 
central station report, audible and visual indications occur and the alarm relay energizes 
during an emergency activation.
The emergency alarm can be triggered by the large EMERGENCY button on the face of the 
Console or with a wireless transmitter. The fi re alarm can be triggered by wireless smoke alarms.
The optional 

activity timer

 can be set for 8, 12 or 24 hour operation. The emergency alarm 

will trigger automatically if the time set elapses before an activity transmitter is triggered or 
the Console’s HOME button is pressed.
If the optional Model VB-4B voice board is installed, the Console will “talk” to the user. 
The digitized voice, will sound “emergency”, “fi re”, “CO Alarm”, “timer done soon”, and 
other system operation, setup, and supervisory prompts from a 38 word vocabulary. In 
addition, the voice board supports 2-way automatic, 2-way manual, and 1-way listen-only 
audio communications with central station monitoring personnel using the Console’s built-in 
high-sensivity microphone and speaker.
The Console can be programmed to act as a remote controlled “speakerphone”. With 
the speakerphone mode enabled (Model VB-4B voice board required) the Console will 
monitor the telephone line for an incoming call. Activating any emergency transmitter (or 
the Console’s EMERGENCY button) while the telephone is ringing will cause the Console 
to seize the line and begin full duplex voice communications. Activating any emergency 
transmitter (or EMERGENCY button) during the call will disconnect the line. The Console 
will auto-disconnect after 15, 30, or 60 minutes (programmable).
Supervised transmitters regularly send status reports to the Console and low battery reports 
when their batteries are low. When the Console receives a low battery report, the TROUBLE 
indicator fl ashes. If the Console fails to receive a status report from a transmitter for a period 
of 24 hours, the TROUBLE indicator will light. All supervisory conditions can sound a local 
annunciation and be reported to the central station.
The Console’s digital communicator can route calls to three telephone numbers: primary, 
secondary, and supervisory. General reporting codes and individual sensor reporting codes 
are programmable for the 4x2 format. Alternately, Ademco Contact ID may be selected for 
the communicator reporting format.
Powered by a low voltage plug-in transformer, the Console has provisions for a rechargeable 
backup battery for operation during AC power outages. A power switch allows for out-of-service 
storage of the Console without discharge of the battery. The battery is recharged and supervised 
by the Console. If the backup battery becomes low the POWER light will fl ash and the condition 
can be reported to the central station. 
The Console is programmed using Linear’s RA-2400 remote access software 

(available on 

CD and at Linear’s Web site: www.linearcorp.com)

.

 

Refer to the software’s built-in help fi le for 

programming details.

TRANSMITTER COMPATIBILITY

OPERATION SUMMARY

A variety of Linear’s supervised DXS and non-supervised DX format transmitters can be 
used with the Console. Transmitters can be assigned to the following four functions:

EMERGENCY

Portable, supervised and non-supervised, pendant, belt-clip, or wristband type transmitters 
(Models DXT-41, DXT-42, DXT-61A, DXS-21, DXS-23, DXS-62A) and stationary, supervised 
Model DXS-31 transmitters are used for medical alert applications. When a medical alert 
transmitter is triggered, the Console sounds a two-tone siren and an emergency report 
is sent to the central station. The emergency alarm can also be triggered by pressing the 
Console’s EMERGENCY button.

FIRE

Supervised Model DXS-73 wireless photoelectric smoke alarms trigger the fi re alarm. 
When the fi re alarm is activated, the Console sounds a repeated series of three beeps and 
a fi re report is sent to the central station.

CARBON MONOXIDE (CO)

Supervised Model DXS-80 wireless carbon monoxide detectors trigger the CO alarm. 
When a carbon monoxide alarm is activated, the Console sounds a repeated series of four 
beeps and a carbon monoxide report is sent to the central station.

ACTIVITY

Supervised, switch or motion triggered transmitters (Models DXS-31/DXS-32 and DXS-54) 
can be used for ensuring human activity. The DXS-54 motion detector will monitor room 
activity. The DXS-31 and DXS-32 transmitters can be wired to a pushbutton or switch for 
manual activity monitoring. As long as a signal is received at least once every 8, 12, or 24 
hours (programmable) an alarm will 

not

 

be triggered. 15 minutes before the programmed 

time expires, the HOME indicator will start blinking and a low pitched beep will sound every 
ten seconds. The activity timer can be reset with a signal from one of the activity transmitters 
or by pressing the HOME button on the Console. Failure to reset the activity timer within 
the programmed time period will cause the Console to sound the two-tone emergency siren 
and send an inactivity report to the central station. The activity timer can be turned on or off 
at the Console or through programming.

1. FRONT PANEL FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
2. REMOVING BOTTOM COVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
3. CONSOLE BOTTOM FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
4. OPTIONAL VB-4B VOICE BOARD INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
5. OPTIONAL RELAY OUTPUT CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
6. OPTIONAL REMOTE SPEAKER/MIC CONNECTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . 2
7. BACKUP BATTERY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
8. INSTALL TRANSFORMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
9. APPLY POWER - SELECT DIALING METHOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
10. TRANSMITTER INSTALLATION OPTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
11. INSTALLING SINGLE TRANSMITTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
12. INSTALLING MULTIPLE TRANSMITTERS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
13. TESTING TRANSMITTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
14. ERASING TRANSMITTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
15. LOCAL PROGRAMMING WITH RA-2400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
16. TELEPHONE CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
17. SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
18. ACTIVITY TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
19. AUDIO BOARD OPERATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
20. SPEAKERPHONE OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
21. SUPERVISORY CONDITIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
22. WIRELESS INSTALLATION TIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SPECIFICATIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
LINEAR LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

PERS-2400B

CONSOLE

EMERGENCY

DXT-61A

DXS-21

DXS-23

DXT-41

DXT-42

FIRE

ACTIVITY

DXS-31

DXS-73

DXS-31/32

DXS-54

R
A
D

I

O

S

I

G
N
A

L
S

TO CENTRAL STATION

VIA TELEPHONE

DXS-62A

CARBON

MONOXIDE

DXS-80

NOTE: COMPATABILITY WITH
THE PERS-2400B HAS NOT
BEEN VERIFIED BY UL

NOTE: NOT A UL LISTED DEVICE

UP TO 16 TRANSMITTERS
CAN BE USED WITH
EACH CONSOLE

Содержание Personal Emergency Reporting System PERS-2400B

Страница 1: ...PERS 2400B PERSONAL EMERGENCY REPORTING SYSTEM USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www linearcorp com Installation and Operation Instructions BY BY...

Страница 2: ...tery becomes low the POWER light will flash and the condition can be reported to the central station The Console is programmed using Linear s RA 2400 remote access software available on CD and at Line...

Страница 3: ...S TO ADD A TRANSMITTER PRESS TO RESET ACTIVITY TIMER PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER OFF IF ACTIVITY TIMER IS OFF PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER ON HOME BUTTON COVER ADHESIVE BA...

Страница 4: ...TO POSITIVE AND BLACK LEAD TO NEGATIVE BATTERY TERMINAL FIT BATTERY INTO CONSOLE SLIDE DOWN THEN BACK OFF ON 2 3 1 PLUG TRANSFORMER INTO AN UN SWITCHED 117 VAC OUTLET SECURE TRANSFORMER WITH SCREW 2 1...

Страница 5: ...RANSMITTER IN THE NEXT AVAILABLE SENSOR ZONE LOCATION IF THE VB 4B VOICE BOARD IS INSTALLED THE CONSOLE WILL ANNOUNCE THE SENSOR ZONE LOCATION NUMBER NOTE WRITE DOWN EACH TRANSMITTER S TYPE AND ZONE N...

Страница 6: ...SOLE S LINE JACK 4 PERFORM THE STEPS DETAILED IN THE RA 2400 PERS 2400 REFERENCE GUIDE P N 217163 TO SET UP THE RA 2400 PROGRAM LINE TO LINE 5 PERFORM PROGRAMMING IN THE RA 2400 SOFTWARE THEN DISCONNE...

Страница 7: ...IONS WHEN EITHER THE EMERGENCY BUTTON IS PRESSED ANY EMERGENCY TRANSMITTER IS ACTIVATED THE AUTO DISCONNECT TIMER RUNS OUT 1 2 3 4 WARNING THE CONSOLE WILL NOT BE ABLE TO REPORT AN EMERGENCY WHILE THE...

Страница 8: ...SMITTER SENDS A LOW BATTERY SIGNAL THE CONSOLE S TROUBLE INDICATOR WILL BLINK SLOWLY IF A TRANSMITTER PROGRAMMED AS SUPERVISED FAILS TO REPORT STATUS IN A 24 HOUR PERIOD THE CONSOLE S TROUBLE INDICATO...

Отзывы: