background image

2

5. OPTIONAL RELAY OUTPUT CONNECTIONS

7. BACKUP BATTERY

6. OPTIONAL REMOTE SPEAKER/MIC CONNECTIONS

8. INSTALL TRANSFORMER

1

2

3 - RELAY COMMON

4 - RELAY NORMALLY OPEN

5

FORM "A" DRY CONTACT RELAY
24 VOLTS AT 1 AMP MAXIMUM

NOISEMAKER OR

VISUAL INDICATOR

EXTERNAL

POWER SUPPLY

PERS-2400A CONSOLE

TERMINAL BLOCK

CONNECT WIRES
TO TERMINALS

ROUTE CABLE UNDER
STRAIN-RELIEF CLAMP

1

TURN POWER
SWITCH OFF

BATTERY TYPE: 12-VOLT, 1.2 AMP/HOUR

CONNECT RED LEAD TO
POSITIVE AND BLACK LEAD TO
NEGATIVE BATTERY TERMINAL

FIT BATTERY
INTO CONSOLE

SLIDE DOWN

THEN BACK

OFF

ON

2

3

1

PLUG TRANSFORMER
INTO AN UN-SWITCHED
117 VAC OUTLET

SECURE
TRANSFORMER
WITH SCREW

2

1 - EXTERNAL SPEAKER

EXTERNAL SPEAKER

3 - RELAY COMMON

4 - RELAY NORMALLY OPEN

5 - DIALER POWER

PERS-2400A CONSOLE

TERMINAL BLOCK

VB-4 TERMINAL BLOCK

EXTERNAL MICROPHONE (+)

MICROPHONE COMMON (-)

CONSOLE MICROPHONE (+)

LINEAR
MODEL RSM-1

RSM-1 TERMINAL BLOCK

SPKR

SPKR

MIC (-)

MIC (+)

VB-4
VOICE
BOARD

RSM-1

TERMINALS

NOTE: REMOVE
JUMPER WHEN

USING AN

EXTERNAL SPKR

NOTE: NOT

TESTED BY UL

DIALER COMMON

2 -

REMOVE

JUMPER

WIRE

USE

SHIELDED

TWISTED PAIR

WIRE FOR

MICROPHONE

Содержание PERS-2400A

Страница 1: ...S 2400A PERSONAL EMERGENCY REPORTING SYSTEM 760 438 7000 FAX 760 438 7043 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com Installation and Operation Instructions BY...

Страница 2: ...ower switch allows for out of service storage of the Console without discharge of the battery The battery is recharged and supervised by the Console If the backup battery becomes low the POWER light w...

Страница 3: ...S TO ADD A TRANSMITTER PRESS TO RESET ACTIVITY TIMER PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER OFF IF ACTIVITY TIMER IS OFF PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER ON HOME BUTTON COVER ADHESIVE BA...

Страница 4: ...TO POSITIVE AND BLACK LEAD TO NEGATIVE BATTERY TERMINAL FIT BATTERY INTO CONSOLE SLIDE DOWN THEN BACK OFF ON 2 3 1 PLUG TRANSFORMER INTO AN UN SWITCHED 117 VAC OUTLET SECURE TRANSFORMER WITH SCREW 2...

Страница 5: ...Y TIMER ENABLED 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED THE CONSOLE WILL RETURN TO OPERATE MODE AUTOMATICALLY AFTER 3 MINUTES 5 DXS 21 DXS 63 NOTE EACH TIME THE TEST BUTTON IS PRESSED IN THE ADD TX...

Страница 6: ...SOLE S LINE JACK 4 PERFORM THE STEPS DETAILED IN THE RA 2400 PERS 2400 REFERENCE GUIDE P N 217163 TO SET UP THE RA 2400 PROGRAM LINE TO LINE 5 PERFORM PROGRAMMING IN THE RA 2400 SOFTWARE THEN DISCONNE...

Страница 7: ...BUTTON OR THE BUTTON ON AN EMERGENCY TRANSMITTER TO END THE PHONE CALL AND THEN PRESS ONE OF THESE BUTTONS AGAIN TO REPORT THE EMERGENCY 3 TIME RUNNING OUT 2 1 ENABLING THE ACTIVITY TIMER PRESS THE HO...

Страница 8: ...ONS WITH THE OPTIONAL MODEL VB 4 VOICE BOARD INSTALLED THE VOICE CAN BE DISABLED THROUGH PROGRAMMING WHEN A TRANSMITTER SENDS A LOW BATTERY SIGNAL THE CONSOLE S TROUBLE INDICATOR WILL BLINK SLOWLY IF...

Отзывы: