background image

6  Testing & Adjusting the Door Force Safety System

The door force adjustments are located on the side of the opener. 

The door force adjustments must be properly 

set at all times. 

The CLOSE FORCE adjustment controls how much force is required to cause the door to reverse 

direction if an obstruction is encountered during closing. The OPEN FORCE adjustment controls how much force 
is required to stop the door if an obstruction is encountered during opening.

➤ 

NOTE:

 Read the following directions carefully before 

changing the door force adjustments. 

Door Force Safety System Test

1

  Start with the door open. 

Use the remote control to 

cycle the door during this test.

 

Adjusting the Close Force

2

  Turn the CLOSE FORCE adjustment 1/8-turn at a time 

in  the  DECREASE  direction  (counterclockwise)  until 

the  door  stops  and  reverses  mid  travel  while  going 

down.

3

  Turn the CLOSE FORCE adjustment 1/8-turn at a time 

in the INCREASE direction (clockwise) until the door 

fully closes without reversing.

 

Safety Reversal System Test

4

  Lay a 2 x 4 board flat on the floor where it will be struck 

by the 

center

 of the door as it closes.

5

  Verify that the door reverses when it strikes the board. 

The  door 

must

  reverse  within  two  seconds  after 

striking the board.

➤ 

NOTE:

 If the door stops after encountering the board 

and does not reverse, the CLOSE FORCE needs to be 
DECREASED.

6

  Repeat the Safety Reversal System Test until the door 

reverses within two seconds of striking the board.

 

Adjusting the Open Force

7

  Turn the OPEN FORCE adjustment 1/8-turn at a time 

in  the  DECREASE  direction  (counterclockwise)  until 

the door stops mid travel while going up.

8

  Turn the OPEN FORCE adjustment 1/8-turn at a time 

in the INCREASE direction (clockwise) until the door 

fully opens without stopping.

7  Replacing the Opener’s Lamps

If either of the opener’s safety lamps fail to light manually 

or  when  the  opener  is  cycled,  the  light  bulb  needs 

replacing. Use the following steps to replace a bad light 

bulb.

1

  Press the release tabs and swing the light cover open 

to expose the light bulb and lamp socket.

2

  Replace the light bulb with a 100 watt maximum rough 

service bulb (sometimes called a garage door bulb).

3

  Swing the light cover closed, snapping it shut.

4

  Press the wall station’s lamp button to test the lamp.

8  Troubleshooting

LAMPS FLASH 

TROUBLE CODE

PROBLEM

CAUSE

REMEDY

1 FLASH

No problem

Remote control entered into 

memory

Add any additional remote controls 

(MegaCode™ type only)

2 FLASHES

Door won’t close

Shorted wall station wires

Check wall station wires. Be sure both are 

connected to the terminal screws.Check for a 

staple in the wall station wires. Remove any 

staples compressing the wire.

3 FLASHES

Door won’t close

Safety beam obstacle

Check for obstacles. Align the safety beam 

(Section 4)

4 FLASHES

Door reverses 

or won’t open or 

close

Open or Close force 

exceeded, or motor thermal 

shutdown

Check for binding or un-balanced door. 

Adjust the door force (Section 6). If motor had 

thermal shutdown, wait 30 minutes and retry.

5 FLASHES

Door won’t open 

from transmitter

Remote was activated while 

vacation switch was locked

Unlock vacation switch on wall station

6 FLASHES

Motor ran longer 

than 30 seconds

Mechanical or electronic 

failure

Call your local garage door professional

FCC NOTICE

Changes or modifications not expressly described in this manual or approved by the manufacturer could void the user’s 
authority to operate the equipment. This device complies with FCC Part 15. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, 
including interference that may cause undesired operation.

LIMITED WARRANTY

This Linear product is warranted to the original consumer against defects in material and workmanship for:

 

MODEL 

ELECTRONICS 

MECHANICAL 

MOTOR 

BELT

 

LSO50 

1 year 

5 years 

Lifetime 

Lifetime

This product is warranted to the original consumer against defects in material and workmanship for the periods mentioned above. Linear 
will repair, or at its option, replace, any device that it finds requires service under this warranty, and will return the repaired or replaced 
device to the consumer at Linear’s cost. Devices must be sent to Linear for service at owner’s expense. This warranty does not apply 
to damage to the product from negligence, abuse, abnormal usage, misuse, accidents, normal wear or tear or due to failure to follow 
Seller’s instructions, or arising from improper installation, storage or maintenance. In no event will Linear be responsible for incidental, 
compensatory, punitive, consequential, indirect, special or other damages. The remedies provided by this warranty are exclusive. Some 
states do not allow the exclusion or limitation of incidental and consequential damages, so the above limitation or exclusion may not apply 
to you. Any warranties implied by law are limited to the time periods set forth above. Some states do not allow limitations on how long an 
implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have 
other rights which vary from state to state.
For warranty service and shipping instructions contact Linear at the phone number shown below. In order to be protected by this warranty, 
save your proof of purchase and send a copy with equipment should repair be required. All products returned for warranty service require 
a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important 
details.

4  Testing the Infrared Safety Beam

The safety beam has two components, a sender and a receiver. The sender produces a narrow infrared beam that 
travels across the bottom of the door opening to the infrared receiver. If an object blocks the infrared beam while the 
door is closing, the door will stop, then reverse and fully open (the opener’s light will flash three times).

As a safety feature, the opener will ignore signals from all remote controls if the door is open and the 
infrared safety beam is blocked or out of alignment. In this case, the door can be forced closed by pressing 
and holding the wall station’s up/down arrow pushbutton (be sure the door area is in clear view).

Safety Beam Test

1

  Check that the opener has power. The green lights on 

the sender and receiver should be lit.

2

  If the receiver’s green light is on, but the red light is off, 

the receiver has power but is not detecting the infrared 

beam from the sender. The red light might flash when 

the beam is partially detected. This can be caused by 

mis-alignment or something blocking the beam. Adjust 

the safety beam sender and receiver while watching the 

receiver’s red light (stay out of the beam while aligning 

it). When the red light stays on, the beam is aligned.

SAFETY BEAM INDICATOR TABLE

GREEN ON

POWER ON

GREEN OFF

POWER OFF

RED ON

BEAM OK - NO BLOCKAGE

RED OFF

BEAM BLOCKED OR MIS-ALIGNED

RED FLASHING

BEAM ALIGNED POORLY

➤ 

NOTE:

 If the receiver’s red light remains off, check 

for: 1) Dirt on the receiver’s lens, 2) Sunlight shining 
into the receiver’s lens, 3) A short in the safety beam 
wiring (from staples or at the opener terminals).

3

 

With the door closed and the opener disengaged 

from  the  door,

  press  the  wall  station’s  UP/DOWN 

ARROW button to move the traveler (the part on the 

belt or chain that the trolley engages with) to the up 

position (away from the door).

4

  Push the wall station’s UP/DOWN ARROW button again. 

While the traveler is moving to the down position (toward 

the  door),  block  the  safety  beam.

  THE  TRAVELER 

MUST STOP, THEN REVERSE TO THE UP POSITION.

 

The opener’s lights should flash three times.

5

  Place an object in the path of the safety beam. Check 

that constant pressure is required on the wall station’s 

UP/DOWN  ARROW  button  to  cause  the  traveler 

to  move  toward  the  down  position.  Release  the 

pushbutton 

before

  the  opener  stops;  check  that  the 

traveler returns to the up position.

➤ 

NOTE:

 The garage door opener will not respond to a 

CLOSE command from a radio transmitter if the safety 
beam is blocked.

6

  To  reconnect  the  opener,  flip  the  release  lever  up. 

Raise the door manually until the opener reconnects.

5  Adjusting the Open and Close Limits

The limit adjustments that control how far the door will 

open or close are located on the side of the opener. The 

limits should be adjusted so the door opens just short of 

any door stops, and closes right at the floor level. Each 

full turn of a limit adjustment equals about 2-½” of door 

travel.

1

  Start with the door in the closed position.

2

  Activate the remote control. Wait while the door moves 

to the open position and stops.

3

  Examine the position of the door.

  •  If  the  door  needs  to  open 

more

,  turn  the  OPEN 

LIMIT  adjustment  clockwise  ¼-turn  (towards  UP  on 

the label) to raise the open limit.

  • If the door needs to open 

less

, turn the OPEN LIMIT 

adjustment counterclockwise ¼-turn (towards DOWN 

on the label) to lower the open limit.

➤ 

NOTE:

 On jamb doors, set the open limit so the door 

stops just short of level (see figure).

4

  Activate the remote control. Wait for the door to move 

down a few feet, then activate the remote control again 

to stop the door.

5

  Repeat  Steps  2-4  until  the  open  limit  is  properly 

adjusted.

6

  Activate the remote control. Wait while the door moves 

to the closed position and stops.

7

  Examine the position of the door.

  •  If  the  door  needs  to  close 

more

,  turn  the  CLOSE 

LIMIT  adjustment  counterclockwise  ¼-turn  (towards 

DOWN on the label) to lower the close limit.

  •  If  the  door  needs  to  close 

less

,  turn  the  CLOSE 

LIMIT  adjustment  clockwise  ¼-turn  (towards  UP  on 

the label) to raise the close limit.

8

  Activate the remote control. Wait for the door to move 

up a few feet, then activate the remote control again to 

stop the door.

9

  Repeat  Steps  6-8  until  the  close  limit  is  properly 

adjusted.

➤ 

NOTE:

 If the door stops during opening or reverses 

during closing before reaching the limits, the door force 
adjustment needs to be set. Change the adjustment as 
described in the next section then return to this step to 
finish setting the limits.

  CAUTION 

Set the open and close limits carefully. Setting 

the limits beyond the distance that the door can 

travel could cause damage to the door, the door 

hardware, or opener.

  WARNING 

Too  much  door  force  will  interfere  with  the 

proper operation of the safety system. SOMEONE 

COULD BE SERIOUSLY INJURED OR KILLED IF THE 

DOOR  FORCE  IS  SET  TOO  HIGH.  A  closing  door 

might  not  reverse  properly  when  required  and 

someone could be pinned under it. An opening 

door might not stop when going up and someone 

hanging on the door could get pinned between 

the  door  and  the  header.  Do  not  increase  the 

door force beyond what is required to move the 

door. DO NOT USE THE DOOR FORCE ADJUSTMENT 

TO  COMPENSATE  FOR  A  BINDING  OR  STICKING 

GARAGE DOOR. PERFORM THE SAFETY REVERSAL 

SYSTEM TEST (STEPS 4-6) MONTHLY!

Copyright © 2004 Linear LLC 

223712 A

PRINTER’S INSTRUCTIONS:

 

INSTR,HOMEOWNERS,LSO W/MCT3; LINEAR P/N: 223712 A; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 11.000” x 17.000”; FOLDING: 1-FOLD VERTICAL, 1-FOLD HORIZONTAL, FINISH 8.500” X 5.500” WITH LOGO SHOWING; SCALE: 1-1; SIDE 2 OF 2 

SAFETY BEAM INDICATORS

RED LIGHT

GREEN LIGHT

GREEN LIGHT

ON = POWER ON
OFF = POWER OFF

RED LIGHT

ON = BEAM ALIGNED, NO OBSTRUCTION
OFF = BEAM NOT ALIGNED, OR OBSTRUCTION

BLINKING = BEAM NEEDS BETTER ALIGNMENT

ADJUST THE SENDER
AND RECEIVER UNTIL
THE RED INDICATOR
LIGHTS SOLID

ADJUSTING THE BEAM

BLOCK THE BEAM

WHILE THE TRAVELER

IS MOVING DOWN

TOWARD

DOOR

TOWARD
OPENER

UP

DOWN

CHECKING FOR REVERSAL

TRAVELER

THE TRAVELER MUST REVERSE

WHEN THE BEAM IS INTERRUPTED

PLACE AN OBJECT

IN THE BEAM'S PATH

VERIFY THAT CONSTANT

PRESSURE IS REQUIRED

ON THE WALL STATION'S

PUSHBUTTON TO MAKE

THE TRAVELER GO DOWN 

RELEASE PUSHBUTTON

BEFORE THE OPENER STOPS,

THE TRAVELER SHOULD

RETURN TO THE UP POSITION

CHECKING FORCED CLOSURE FEATURE

  WARNING 

With  the  door  closed,  disengage  the  trolley 

from the chain during these alignment tests by 

pulling the red release handle.

  WARNING 

Serious injury or death from a closing garage 

door may result because of failure to test and 

adjust safety reverse system. Repeat this test 

monthly and adjust as needed.

USE A SCREWDRIVER TO
ADJUST THE OPEN LIMIT

SETTING THE OPEN LIMIT

OPEN LIMIT

ADJUSTMENT

UP

DOWN

CLOSE LIMIT

ADJUSTMENT

UP

DOWN

USE A SCREWDRIVER TO
ADJUST THE CLOSE LIMIT

SETTING THE CLOSE LIMIT

DOWN

UP

EXAMINE THE SPOT WHERE
DOOR STOPS CLOSING

CHECKING WHERE THE DOOR STOPS

DOWN

UP

EXAMINE THE SPOT WHERE
THE DOOR STOPS OPENING

CHECKING WHERE THE DOOR STOPS

ADJUSTING THE

CLOSE FORCE

ADJUSTING THE

OPEN FORCE

SETTING THE DOOR FORCE

CLOSE FORCE

DECREASE

DECREASE CLOSE FORCE
ADJUSTMENT UNTIL THE
DOOR REVERSES MIDWAY

WHILE GOING DOWN

UNDER-SETTING THE CLOSE FORCE

TEST WITH SMALL OBSTACLE

THE DOOR MUST REVERSE
WITHIN 2-SECONDS AFTER

IMPACT WITH A 2 x 4 BOARD

2 x 4 BOARD LAID FLAT
UNDER CENTER OF DOOR

TESTING THE SAFETY REVERSAL SYSTEM

OPEN FORCE

DECREASE

DECREASE OPEN FORCE
ADJUSTMENT UNTIL THE
DOOR STOPS MIDWAY

WHILE GOING UP

OPEN FORCE

INCREASE

INCREASE OPEN FORCE
ADJUSTMENT UNTIL THE
DOOR OPENS FULLY

WITHOUT STOPPING

UNDER-SETTING THE OPEN FORCE

SETTING THE OPEN FORCE

CLOSE FORCE

INCREASE

INCREASE CLOSE FORCE
ADJUSTMENT UNTIL THE

DOOR CLOSES FULLY

WITHOUT REVERSING

SETTING THE CLOSE FORCE

REPLACING LAMPS

PRESS RELEASE TABS TO
OPEN LIGHT COVER

REPLACE LAMPS WITH
UP TO 100 WATT
ROUGH SERVICE TYPE
LIGHT BULBS 

  WARNING 

Always  perform  the  Door  Force  Safety  System 

Test  after  making  any  adjustments  to  the 

opener.

SETTING THE OPEN LIMIT ON A JAMB DOOR

JAMB DOOR

SET THE OPEN LIMIT SO THE DOOR
STOPS JUST SHORT OF LEVEL

NOTE: SETTING THE OPEN LIMIT TOO HIGH WILL CAUSE
THE OPENER TO "BUCK" WHEN STARTING DOWN

Отзывы: