Step 1. Install the IEI PowerKey AC following installation instructions.
Step 2. Make a list of users and the code numbers you wish to assign to each of them. The codes may be 1 - 6 digits long.
Users can be programmed with a “type” designation to perform different functions:
Type 1 - A normal user which may start and operate the controlled equipment
Type 3 - A lock out user code which prevents all Type 1 users from operating the equipment.
Users List:
User Number
Name
Code Number
Type
01
John Smith
5678
1
02
__________________
__________________
____
03...99
__________________
__________________
____
Step 3. Defi ne the operating parameters of the controlled equipment. After a valid code is entered power is available to the
saw (for example). The operator may start or stop the saw as necessary. A timer in the PowerKey AC starts each time the
saw is stopped. If the saw is stopped for longer than the programmed time, the power will be turned off. The operator must
reenter the code to use the saw again. Determine a time from 10-990 seconds that you think would be required for the
operator to set up the saw between cuts.
PROGRAMMING:
Once you have prepared the information above you are ready to begin programming. To access the
programming mode on the PowerKey AC, press the following sequence on the keypad: 99 # Master code *
The master code is always assigned to user #1. This code comes from the factory as 1234. You should
change this to your own number. To enter programming mode for a new unit press: 99 #1234* When the
PowerKey AC is in programming mode, the Yellow LED fl ashes about once a second.
While you are in programming mode you may use the following command sequences to program functions.
To exit programming mode press the * key several times or wait 45 seconds and the unit will return to normal
automatically.
Function:
Programming Command:
Enter (or change) user
50 #
Type (1 or 3)
#
User Number (01-99)
# code * repeat code *
Delete user
50 #
Type (1 or 3)
#
User Number (01-99)
# * *
Set shut off time
(Default shut off time is 15 seconds)
85 #
Time (10-990)
#
0
# * *
Clear memory/Reset Defaults
46 #
00000
#
00000
# * *
The Yellow LED will fl ash fast after you enter a new code number and go back to slow fl ash on repeat entry. A
steady Yellow indicates a mistake. Press * to go back to programming.
Normal Operation:
EVENT
ACTION
LED STATUS
To turn on power
Enter Code number and * key
Led turns from Red to Green
To turn off power
Press and hold any key or keys
Led turns from Green to Red
Automatic shut off
Controlled equipment turned off
Green LED on for programmed shut off time period
LED fl ashes GREEN for last 10 seconds
Then power is off to equipment
To lock out users:
Enter lock out code (see above)
Then RED LED fl ashes
To unlock users:
Enter lock out user code again
LED returns to steady RED