background image

GSLG-A OPERATOR INSTALLATION GUIDE

- 6 -

Assemble a gate bracket (1) to the front edge of the gate, 
using two U-bolts (2), and mounting hardware (3). Before 
tightening down completely, be sure the bracket is paral-
lel to the gate. Tighten the U-bolt hardware the rest of the 
way, then screw the square head bolts (4) into the threaded 
holes in the gate plate until they bottom out against the 
gate.  These will help keep the bracket from twisting on 
the pipe.

Slide a threaded chain pin (5) through the bracket as shown, 
with spring (6), fl at washer (10), and two hex nuts (7).
Attach one end of the drive chain (8) to the chain pin using 
master link (9) and begin unrolling it toward the operator.

Remove the rain cover from the back of the slide gate op-
erator. Carefully thread the drive chain under the fi rst idler, 
over the drive sprocket, and then under the last idler. Make 
sure you feed most of the chain through the sprockets for 
attaching to the back end of the gate.

Assemble the other gate bracket on the rear edge of the 
gate, using the same process as you did with the front gate 
bracket. Once this is done, take the other chain pin, spring 
and jam nuts and assemble with the end of drive chain and 
the other master link.

At this point you should be able to adjust the chain tension 
by tightening the jam nuts on each end. Approximately 1/4” 
to 3/8” of slack per foot of drive chain is acceptable. Make 
sure the chain does not drag on the ground, across the 
gate rollers or the idler frame of the operator.

Additional mounting holes have been provided in the gate 
bracket for installer convenience.

GATE BRACKET AND CHAIN ASSEMBLY INSTRUCTIONS

Numbered items in these 
drawings are for instruc-
tional reference only. For 
actual part numbers, go to 
the parts lists in the back of 
this booklet.

Содержание GSLG-A

Страница 1: ...L325 COMPLIANCE REQUIRES THE USE OF CONTACT EDGES OR PHOTOELECTRIC CONTROLS ON ALL AUTOMATIC OR REMOTELY CONTROLLED GATE OPERATORS USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 4...

Страница 2: ...tion 11 Onboard L E D Indicator Descriptions 12 Important Notes for Installation of Master Slave Applications 13 Surge Protector Instructions 13 Control and Accessory Connection Illustrations 14 17 IL...

Страница 3: ...gate does not seem to operate properly it may affect the operator performance or greatly shorten the life of the unit The gate should be designed so that airflow through the fabric is ample to prevent...

Страница 4: ...9 for details of this connection as well as dip switch selection Note The SHIELD wire should be connected in both the master and slave operators e s a h P 3 g n i r i W r e w o P s t l o V P H e c n...

Страница 5: ...here are six 3 16 side plates which should be mounted on the outside top and bottom of the cabinet two 3 16 side plates which go on the top inside and two 1 2 side plates which should be mounted on th...

Страница 6: ...idler over the drive sprocket and then under the last idler Make sure you feed most of the chain through the sprockets for attaching to the back end of the gate Assemble the other gate bracket on the...

Страница 7: ...good working condition One person should be able to move the gate by hand Be certain the gate moves freely and without binding throughout its travel Torque limiters are set light at the factory and mu...

Страница 8: ...operator after the limit switch is tripped Once the gate is in this position adjust the open limit nut until it activates the limit switch for open LSO 1 Press down on the detent plate and rotate the...

Страница 9: ...of obstructions while running in the closed direction Master Slave Connection Block This terminal block is used in conjunction with two operators to configure two gates to open and close together Dip...

Страница 10: ...ain prior to reaching a limit the gate will stop again and this time will sound the emergency alarm and lock out 4 51 CLOSE This function works exactly like the OPEN OBSTRUCTION except that it will on...

Страница 11: ...otentiometer higher by 1 1 2 turns for all 115 Volt AC and 24 Volt DC operators and by 3 4 of a turn higher for all 230 Volt AC operators Additional fine adjustment by 1 4 turns may be necessary to el...

Страница 12: ...tor wired to the safety loop terminals SHADOW LOOP This indicator is lit when a shadow hold open signal is present This signal is generated by a loop detector wired to the shadow loop terminals This i...

Страница 13: ...nd Lock Release Three Second Pre Start Warning Right Left Hand Selections SURGE PROTECTOR INSTRUCTIONS The optional surge protector should be connected to any inputs that have an accessory connected t...

Страница 14: ...GSLG A OPERATOR INSTALLATION GUIDE 14 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Страница 15: ...GSLG A OPERATOR INSTALLATION GUIDE 15 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Страница 16: ...GSLG A OPERATOR INSTALLATION GUIDE 16 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Страница 17: ...GSLG A OPERATOR INSTALLATION GUIDE 17 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Страница 18: ...GSLG A OPERATOR INSTALLATION GUIDE 18 LOOP LAYOUT ILLUSTRATION Refer to Connection Descriptions on page 10 and Loop Accessory Connections on page 17 for details...

Страница 19: ...GSLG A OPERATOR INSTALLATION GUIDE 19 EDGE LAYOUT ILLUSTRATION 1 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 16 for details...

Страница 20: ...GSLG A OPERATOR INSTALLATION GUIDE 20 EDGE LAYOUT ILLUSTRATION 2 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 16 for details...

Страница 21: ...GSLG A OPERATOR INSTALLATION GUIDE 21 PHOTO EYE ILLUSTRATION Refer to Connection Descriptions on page 10 and Photo Eye Connections on page 16 for details...

Страница 22: ...GSLG A OPERATOR INSTALLATION GUIDE 22 PICKET GATE ILLUSTRATION Refer to Connection Descriptions on page 10 and Accessory Connections on pages 14 17 for additional details...

Страница 23: ...GSLG A OPERATOR INSTALLATION GUIDE 23 TRACK GATE ILLUSTRATION...

Страница 24: ...rent sensing set too low Make sure the gate moves freely through its entire travel before ad justing the current sensing B The maximum run timer may have counted down and expired This can be caused by...

Страница 25: ...GSLG A OPERATOR INSTALLATION GUIDE 25 MODEL GSLG A MECHANICAL PARTS EXPLODED VIEW...

Страница 26: ...s 2500 034 Power Switch only REF NO PART NO DESCRIPTION 46 2100 1756 Mounting Plate 47 2100 1781 Accessory Shelf for single phase models only 33 2400 308 Fender Washer 3 8 34 2400 017 Flat Washer 3 8...

Страница 27: ...y 10 2510 249 Input Wire Harness Assembly 11 2510 250 Output Wire Harness Assembly 12 2510 261 Control Box Motor Harness Assembly 13 2500 071 Terminal Strip 16 141 14 2500 212 Transformer 115 24VAC 40...

Страница 28: ...0 268 Control Board only 10 2500 1980 3 Phase Motor Board 11 2500 1966 2 Amp Fuse for Control Board 12 2500 1975 3 Amp Fuse for Control Board 13 2510 253 Limit Switch Harness REF NO PART NO DESCRIPTIO...

Страница 29: ...ar the source Laboratory samples should be handled in a fume hood Provide mechanical ventilation of confined spaces HANDLING STORAGE AND SHIPPING Keep containers closed Handle and open containers with...

Страница 30: ...lace as necessary Check for proper tension and adjust if required Check all pulley setscrews for tightness and tighten if necessary 3 For operators with internal chain drives inspect chain and sprocke...

Страница 31: ...GSLG A OPERATOR INSTALLATION GUIDE 31 This page intentionally left blank...

Страница 32: ...d that these signs must remain at all times 8 Controls intended for user activation are located at least six feet 6 away from any mov ing part of the gate and where the user is prevented from reaching...

Отзывы: