background image

18

LOCAL PROGRAMMING ACCESS

Programming with a Local Telephone or the Unit’s Keypad

Start with Step 1 below for local programming with the unit’s keypad 
or a local telephone.

1. Enter 

###

” (unless the programming prefi x has been changed) then 

the Master Programming Code (123456, unless it has been changed), 
then “

#

”.

2.  Use the telephone keys or keypad to make any programming 

changes. 

Refer to the next section for details of the 

keystrokes for each programming PPN. 

The voice 

synthesizer will sound programming prompts.

3.  To disconnect after programming, enter “

99#

”.

 

NOTE:

 The RE-1 will automatically exit programming mode after fi ve 

minutes of no programming activity.

REMOTE PROGRAMMING ACCESS

Remote Programming with a Telephone

For remote programming, the RE-1 can be called from any 
TouchTone® telephone. Once the connection is made, the 
programming keystrokes are identical to what would be entered at 
the unit’s keypad or from a local telephone. Refer to the next section 
for details of the keystrokes for each programming PPN.

Remote Telephone Connection

1.  Dial the telephone number of the line that the RE-1 is connected to.
2.  Let the telephone ring twice and hang up.
3.  After 10 seconds, but before 30 seconds, call back to the same 

telephone number.

4.  The RE-1 will answer and sound a tone for 2 seconds.
5.  The RE-1 will wait for approximately six seconds for the caller to enter 

the Master Programming Code.

6.  Enter password (123456, unless it has been changed), then “

#

”.

7.  Use the telephone keypad to make any programming changes. Refer 

to the next section for details of the keystrokes for each programming 
PPN. The voice synthesizer will sound programming prompts.

8.  To disconnect after programming, enter “

99#

”.

Содержание ACP00892

Страница 1: ...ential Telephone Entry System With Built in Wireless Receiver 760 438 7000 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com Installation Programming and Operation Ins...

Страница 2: ...SUPPORT BRIGHT WHITE LED DOWNLIGHT PIEZO SOUNDER 2 HEAVY DUTY FORM C N O N C RELAY OUTPUTS TIMED ANTI PASSBACK KEYPAD LOCKOUT TACTILE KEY FEEL TWO DOOR SENSE INHIBIT INPUTS TWO OPEN REQUEST INPUTS AC...

Страница 3: ...ss through the RE 1 s built in radio receiver Each transmitter can be individually suspended or re activated One facility code can be programmed to identify each block of transmitters Programming of i...

Страница 4: ...size of 18 AWG for up to 3600 feet DO NOT ROUTE TELEPHONE AND AC WIRING INSIDE THE SAME CONDUIT Route all telephone wires inside a dedicated conduit that is at least six inches away from any AC line...

Страница 5: ...metal 12 key keypad with tactile action For system programming and keying in entry codes 2 DOWNLIGHT Illuminates keypad and visitor operation buttons The light can be programmed to operate dusk to da...

Страница 6: ...TRIC DOOR STRIKE MAGNETIC DOOR LOCK ACCESS DEVICE POWER SUPPLY NOTE A MAGNETIC LOCK AND DOOR STRIKE ARE BOTH SHOWN TYPICALLY ONLY ONE IS USED 16 VAC 20 VA TRANSFORMER TELCO OPEN 1 KEYPAD GND KEYPAD DA...

Страница 7: ...connected to the line ahead of the Telephone Bypass Module using a RJ 31X or RJ 38X interface Use only high quality telephone wire rated for direct underground burial All telephone wire should be twi...

Страница 8: ...ediate communications with the PBX system See PPN 54 for programming options TELCO RING TIP RING TIP EARTH HOUSE TIP RING TIP RING TIP RING TIP RING TELCO RE 1 TELCO RE 1 HOUSE HOUSE TELEPHONE BYPASS...

Страница 9: ...cing the second RE 1 Simultaneous visitors at multiple units used on a single line wired in the Ring Down Mode will cause a conference call effect between units Figure 10 Multiple Unit Wiring TIP RING...

Страница 10: ...wiring and installation 6 To use the door sense feature to detect forced entry or door ajar conditions install a normally closed door switch on the door or pedestrian gate and route two wires from th...

Страница 11: ...amps installed by the Power or Telephone Company Alternately connect to a cold water pipe for the earth ground 1 Connect the RE 1 EARTH terminal to the earth ground wire 2 Connect the Telephone Bypass...

Страница 12: ...O pins see Figure 21 5 Replace the RE 1 circuit board Secure the board with the four screws Reconnect the antenna terminal block and wiring harness connector 6 Connect one keyswitch wire to the RE 1 O...

Страница 13: ...wiring harness 2 pin lighting power wiring connector onto the camera s infrared lighting power connector see Figure 25 4 Replace the RE 1 circuit board Secure the board with the four screws Reconnect...

Страница 14: ...dragged to the desktop for easy future access 4 Enter the RE 1 s programming master password 123456 unless changed into the Password area Select Save Password if you want the computer to retain the pa...

Страница 15: ...NTER 192 168 20 11 THEN CLICK ADVANCED 14 UN CHECK USE DEFAULT GATEWAY ON REMOTE NETWORK AND UN CHECK USE IP HEADER COMPRESSION THEN CLICK OK SETTING UP A WINDOWS XP DIAL UP NETWORK CONNECTION BE SURE...

Страница 16: ...0 10 re1 html 3 THE MODEM WILL DIAL THE NUMBER CONNECTING TO THE RE 1 WITH WINDOWS XP 1 DOUBLE CLICK ON DESKTOP ICON TO LAUNCH THE CONNECTION WINDOW 5 THE RE 1 WILL VERIFY THE USERNAME AND PASSWORD 4...

Страница 17: ...NDOWS VISTA DIAL UP NETWORK CONNECTION PART 1 2 CLICK ON SETUP A CONNECTION OR NETWORK 3 CHOOSE SET UP A DIAL UP CONNECTION 4 CLICK ON THE MODEM TO BE USED FOR THE CONNECTION 5 FILL IN THE INFORMATION...

Страница 18: ...9 IN THE CONNECT WINDOW SELECT PROPERTIES 10 CLICK ON CONFIGURE AND UN CHECK ALL HARDWARE FEATURES 11 CLICK ON OK THEN CLICK ON NETWORKING TAB HIGHLIGHT INTERNET PROTOCOL VERSION 4 TCP IPv4 AND CLICK...

Страница 19: ...CONNECTING REMOTELY AFTER THREE RINGS CLICK CANCEL WAIT 10 SECONDS THEN REPEAT STEPS 1 3 THE RE 1 WILL ANSWER THE PHONE ON THE SECOND CALL ATTEMPT 5 AFTER CONNECTING SWITCH TO YOUR MICROSOFT INTERNET...

Страница 20: ...1 can be called from any TouchTone telephone Once the connection is made the programming keystrokes are identical to what would be entered at the unit s keypad or from a local telephone Refer to the...

Страница 21: ...RASING ALL ENTRY CODES PPN 97 PAGE 20 CHANGING THE MASTER CODE PPN 98 PAGE 20 RESET SYSTEM DEFAULTS PPN 200 PAGE 22 FACTORY DEFAULTS PPN 1 ENTRY CODE LENGTH 4 DIGITS PPN 8 TRANSMITTER LEFT OR TOP LEFT...

Страница 22: ...thod code or transmitter is assigned to a time zone holidays must be set as an active day to allow access on holidays Press Holiday Number Month Day Holiday Number 1 10 Month 1 12 Day 1 31 ENTRY CODE...

Страница 23: ...econd during the last ten seconds of time allowed Press Limit Limit 15 255 Seconds allowed Call Waiting Feature On Off Default On Turns the call waiting feature on or off If call waiting is on factory...

Страница 24: ...extension number Delay 1 25 seconds delay between telephone number and extension Resident Response Telephone Keys Defaults Key A 1 Activates Relay 1 Key B 2 Activates Relay 2 Key C 9 Disconnect Visit...

Страница 25: ...ear Model AM KP is used as a remote keypad the ADDRESS switch in the remote keypad needs to match the address setting in the RE 1 For most installations simply set the remote keypad s ADDRESS switch t...

Страница 26: ...time will change on the first Sunday in April and on the last Sunday of October For areas where daylight saving time is not observed this feature may be disabled Press Daylight Saving Daylight Saving...

Страница 27: ...feature is enabled the system will forward the visitor s call to an outside telephone number during the programmed time for call forwarding The resident can control access from the forwarded telephon...

Страница 28: ...on Facility Facility code 1 16 of transmitter 0 no facility code ID 5 digit ID number of transmitter Action 0 Suspend transmitter 1 Re activate transmitter Maximum Number of Visitor Rings Press Rings...

Страница 29: ...16 VAC wires from terminal strip if buzz goes away one side of the transformer wires is grounded 3 Check all connections for any shorts to ground Telephones in residence will not ring 1 Verify that t...

Страница 30: ...P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H...

Страница 31: ...2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1 _ _ 2 _ _ 1...

Страница 32: ...eiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies regardless of code settings Changes or modifica...

Отзывы: