background image

2

dc1987af

DEMO MANUAL DC1987A

Quick start proceDure

Demo circuit 1987A provides an easy method to evalu-

ate the performance of the LTM8057. Refer to Figure 3 

for proper measurement equipment setup and follow the 

procedure below:
NOTE. When measuring the input or output voltage ripple, 

care must be taken to avoid a long ground lead on the 

oscilloscope probe. Measure the input or output voltage 

ripple by touching the probe tip directly across the VIN or 

VOUT and GND terminals. See Figure 4 for proper scope 

probe technique.
1. With power off, connect the input power supply to VIN 

and GND.

2. Turn on the power at the input.
  NOTE.  Make  sure  that  the  input  voltage  does  not  

exceed 29V.

3. Check for the proper output voltage. (For V

OUT

, check 

the voltage between VOUT and VOUT–)

  NOTE. If there is no output, temporarily disconnect the 

load to make sure that the load is not set too high.

4. Once the proper output voltages are established, adjust 

the load within the operating range and observe the 

output voltage regulation, ripple voltage, efficiency and 

other parameters.

performance summary

Specifications are at T

A

 = 25°C

PARAMETER

CONDITIONS

MIN

TYP

MAX

UNITS

Minimum Input Voltage

4.5

V

Maximum Input Voltage

29

V

Output Voltage V

OUT

 

V

IN

 = 4.5V – 29V

4.75

5.25

V

Voltage Ripple V

OUT

V

IN

 = 12V, I

OUT

 = 100mA

10

mV