DEMO MANUAL DC1623A

QUICK START PROCEDURE

Demonstration circuit DC1623A is an easy way to evalu-
ate the performance of the LTM8033. Refer to Figure 1 
for proper measurement equipment setup and follow the 
procedure below:

NOTE: When measuring the input or output voltage ripple, 
care must be taken to avoid a long ground lead on the 
oscilloscope probe. Measure the input or output voltage 
ripple by touching the probe tip directly across the terminals 
of the input or output capacitors. See Figure 2 for proper 
scope probe technique.

1. Place JP1 in the ON position. 

2. With power off, preset the input power supply within 

the operating input voltage range and connect to V

IN

 

and GND.

3. Turn on the power at the input. 

4. Check for the proper output voltage.

NOTE: If there is no output, temporarily disconnect the load 
to make sure that the load is not set too high or is shorted.

5. Once the proper output voltage is established, adjust 

the loads within the operating range and observe the 
output voltage regulation, ripple voltage, efficiency and 
other parameters. 

6. An external clock can be added to the SYNC pin when 

SYNC function is used. See the Synchronization section 
in the data sheet for details.