background image

2

dc2073bfa

DEMO MANUAL DC2073B

QUICK START PROCEDURE

Test Equipment:

1. A single 3V power supply.
2. An oscilloscope with a bandwidth of at least 5x f

OSC

(For example, if f

OSC 

= 100MHz then use a 500MHz 

oscilloscope).

3. A screwdriver to adjust the potentiometer.
 

Note:

 The DC2073B potentiometer is shorted with a 

zero ohm resistor for factory testing. The zero ohm 

(RJ10) resistor must be removed to allow setting the 

frequency with a screwdriver. If the potentiometer is 

set to a high value (>100k), then touching the DC2073B 

can produce output jitter.

Basic Test Procedure:

1. Connect power supply to V

+

 and GND, turrets E4 and E5.

2. Connect oscilloscope probe to OUT1 and GND. 
  Note: The ground lead of an oscilloscope probe has a 

series inductance that can generate a resonant circuit 

with the probe's capacitance. Probe resonance adds 

transient  peaks  and  ringing  on  a  high  speed  wave-

form. Reliable probing of the high frequency LTC6905 

and LTC6905-XXX (with corresponding demo boards 

DC2073B-A, -D, -E, -F or -G), must use a very short 

connection of the oscilloscope probe ground to the board 

GND (see probe tip picture in Figure 1 Test Setup).

3. Set the JP1 jumper to the N divider position for the 

desired frequency shown on Table2.

4. Turn on supply. 
5. The  oscilloscope  display  shows  a 3V  squarewave  

(0V to 3V).

6. For the resistor-set ICs (DC2073B-A, -B, -C, -H, -I, -J 

or -K) turn the RPOT potentiometer for the desired fre-

quency. (The frequency adjustment is very coarse when 

the potentiometer is turned near the fully clockwise or 

counter-clockwise position).

Verify Oscillator Accuracy

The f

OSC

 accuracy of the resistor-set ICs (DC2073B-A, -B, 

-C, -H, -I, -J or -K), can be verified by setting RSET to the 

exact value from the f

OSC

 equation shown in Table 2. For 

the DC2073B-A, -B, -C, -J, -K, RSET = RPOT + RSET2. 

RSET1 and RSET2 are never installed on the same board. 

Connecting  an  ohmmeter  across  RPOT  and  RSET1  or 

RSET2 forces current into the IC set pin (Pin 3 or 4) and 

causes an error in the ohmmeter reading. The RS resistor 

is in series with RPOT and equal to RSET1 or RSET2 and 

the equivalent RSET = RPOT + RS.

Procedure to Verify Oscillator Accuracy 

a. Calculate RSET for the desired frequency (RSET in Table 2).
b. Remove the power supply leads from DC2073B and con-

nect an ohmmeter from POT (E6) to V

+

 (DC2073B-A, 

-B, -C, -J or -K) or GND (DC2073B-H or-I).

C. Adjust RPOT for the exact value of RSET needed.
  Note: If the potentiometer is turned near the fully clock-

wise or counter-clockwise position the RPOT adjustment 

may be too coarse for setting an exact RSET value. In 

addition, for a frequency adjustment near the upper or 

lower f

OSC

 range, RSET may be greater or less than the 

default DC2073B RPOT + RSET1 or RSET2 value, in this 

case the RSET1 or RSET2 resistor must be removed 

and replaced with a lower or higher value.