Q U ICK  START PROCEDU RE 

Demonstration circuit 1363 is easy to set up to evaluate 
the  performance  of  the  LT6107.  Refer  to  Figure 1  for 
proper  measurement  equipment  setup  and  follow   the 
procedure below :  

1. 

W ith pow er off, connect the pow er supply positive to 
IN and the common to G N D. This supply should be in 
the range of 2.7V to 36V. If this supply is not equipped 
w ith  an  accurate  current  readout,  a  DM M   (set  to 
measure  Amperes)  may  be  connected  in  series  w ith 
the supply as show n in Figure 1. 

NOTE. 

Be sure that the current capacity of the DM M  is adequate to 

handle the intended load current. 

2. 

Connect a voltmeter or oscilloscope probe to the M O N  
terminal, w ith the common connection or ground clip 
tied to G N D. 

3. 

Connect  a  load  to  the  O U T  terminal  (positive)  and 
return (negative) to the common of the pow er supply. 
The  load  may  be  a  pow er  resistor,  active  load 
instrument, or other circuit of interest. 

4. 

Turn on the pow er supply.  

5. 

M easure  an  output  voltage  that  corresponds  to  the 
load current. V

M ON

 = 0.5

×

I

OUT

 for the factory installed 

resistors.

 

 

 

 

 

LOAD 

(10

+   COM 

POWER 

SUPPLY

 

DMM 

A COM V 

DMM 

A COM V 

 

Figure 1. Proper M easurem ent Equipm ent Setup 