QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 612 

BOOST CONVERTER 

 

 

2

 

QUICK START PROCEDURE 

Demonstration  circuit  612  is  easy  to  set  up  to  evaluate 
the  performance  of  the  LT3464ETS8.  Refer  to  Figure 1 
for proper measurement equipment setup and follow the 
procedure below:  

NOTE:

 

When measuring the input or output voltage ripple, 

care  must  be  taken  to  avoid  a  long  ground  lead  on  the 
oscilloscope probe. Measure the input or output voltage 
ripple by touching the probe tip directly across the Vin or 
Vout  and  GND terminals.  See  Figure 2 for proper  scope 
probe technique. 

1.

 

Make sure the SHDN jumper is in the ON position and 
the CNTL jumper is in the INT REF position. 

2.

 

Turn on the input voltage source and set it to 3.6V. 

3.

 

Monitor the output voltage. For the small size circuit, 
the  output  voltage  should  be  20.0V ±4%  and  for  the 

high performance circuit, the output voltage should be 
15.0V ±4%. 

4.

 

Apply  the  full  rated  load  to  the  output  for  an  input 
voltage of 3.6V. For the small size circuit, this is 3mA 
and for the high performance circuit, this is 9mA. The 
output voltage should still be within regulation. 

5.

 

With full rated load applied and with the input voltage 
still at 3.6V, measure the input current. For the small 
size  circuit,  the  input  current  should  be  less  than 
31.0mA.  For  the  high  performance  circuit,  the  input 
current should be less than 54.0mA.  

6.

 

Once  the  proper  output  voltages  are  established,  ad-
just the loads within the operating range and observe 
the output voltage regulation, ripple voltage, efficiency 
and other parameters. 

 

Figure 1.

 

Proper Measurement Equipment Setup 

V

IN

G

N

D

  

Figure 2.

 

Measuring Input or Output Ripple 