2
dc1622af
DEMO MANUAL DC1622A
QUICK START PROCEDURE
Figure 1. Proper Measurement Equipment Setup
Demonstration circuit 1622A is easy to set up to evalu-
ate the performance of the LT3032. Refer to Figure 1 for
proper measurement of the equipment setup and follow
the procedure below:
1. Place JP1 and JP2 on the ON position.
2. Use OUTP and OUTN selection J1, J2 to set the desired
output voltage.
3. With power off, connect the input power supply to ±VIN
and GND.
4. Turn on the power at the input.
Note: Make sure that the input voltage does not exceed ±20V.
5. Check for the proper output voltage.
Note: If there is no output, temporarily disconnect the load
to make sure that the load is not set too high.
6. Once the proper output voltage is established, adjust the
load within the operating range and observe the output
voltage regulation, efficiency and other parameters.
Note: Make sure that the power dissipation is limited below
the thermal limit.
LOAD
LOAD
V
+
–
V
+
–
A
–
+
A
–
+
+
V
+
–
A
–
+
+
V
+
–
A
–
+
DC1622A F01