background image

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 474 

4A, 500KHZ STEP DOWN SWITCHING REGULATOR

 

4. 

To turn the circuit off, ground the 
terminal labeled SHDN 

5. 

To test the synchronization feature 
of the demo board apply a sync sig-
nal to the sync terminal and note 
the shift in the operating fre-
quency. The Sync signal should have 
an amplitude greater than 2.2V, 
duty cycle of between 10% and 90% 
and a frequency of 580kHz–1000kHz 

MEASUREMENT NOTES 

Voltage measurements 

The correct way to measure voltage is 
at the terminal of the demo board. 
Attempts to measure output voltage at 
the load will result in a too low 
output voltage due to wiring loss. 

This is especially true at high cur-
rent. Needless to say any efficiency 
calculation should be made using demo 
circuit terminal voltages as opposed 
to load or power source terminal 
voltages. 

Ripple Voltage Measurements 

The ceramic capacitors used in this 
demo board have almost no ESR and are 
extremely effective filters. In order 
to correctly measure output ripple 
voltage correct technique is impor-
tant. The scope ground lead and 
sheath should be removed and the out-
put ripple measured by placing the 
scope probe directly across the out-
put Vout and GND pins as illustrated 
in Figure 4.  

 

 

5V TO 25V

SUPPLY

25W

+

+

+

+

+

+

LOAD

 

Figure 3. 

Proper Measurement Equipment Setup 

 

 

 

 

 

2

 