Linear Technology DEMONSTRATION CIRCUIT 518 Скачать руководство пользователя страница 2

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 518  

SLIC POSITIVE INPUT TO NEGATIVE OUTPUT DC/DC CONVERTER

 

 

 

2

 

NOTE: 

Make sure that the input voltage does not 

exceed  15V. 

4.  Check for the proper output voltages.  V

OUT1  

= -24V 

and V

OUT2  

= -70V  

 

If there is no output, temporarily disconnect the       

 

load to make sure that the load is not set too high.

 

5. 

Once the proper output voltage is established, 
adjust the load within the operating range and ob-
serve the output voltage regulation, ripple voltage, 
efficiency and other parameter

 

 
 
 

 
 
 

Figure 1.

 

Proper Measurement Equipment Setup 

 

Figure 2.

 

Scope Probe Placement for 

Measuring Input or Output Ripple 

 