Linear Technology DEMO CIRCUIT 1672A Скачать руководство пользователя страница 3

LTC3816EUHF 

 

 

QUICK START PROCEDURE 

Demonstration circuit 1672A is easy to set up to eva-
luate the performance of the LTC3816EUHF.  Refer to 
Figure 1 for the proper measurement equipment se-
tup and jumpers’ location, and follow the procedure 
below: 

 

 

1.

 

With power off, connect the input power 
supply to Vin (4.5V-28V) and GND (input re-
turn). 

2.

 

Set VID jumpers VID6-0: 0110000 for 0.9V ou-
put. 

3.

 

Connect the output load between Vout and 
GND (Initial load: no load). 

4.

 

Connect the DVMs to the input and outputs. 

5.

 

Turn on the input power supply and check for 
the proper output voltages. Vout should be 
within 0.885 V to 0.915V.  

6.

 

Once the proper output voltages are estab-
lished, adjust the loads within the operating 
range and observe the output voltage regula-
tion, ripple voltage and other parameters. 

 

Note: When measuring the output or input voltage 
ripple, do not use the long ground lead on the oscil-
loscope probe. See Figure 2 for the proper scope 
probe technique. Short, stiff leads need to be sol-
dered to the (+) and (-) terminals of an output capaci-
tor. The probe’s ground ring needs to touch the (-) 
lead and the probe tip needs to touch the (+) lead.

Содержание DEMO CIRCUIT 1672A

Страница 1: ... temperature compensated inductor DCR or sense resistor output current monitoring The LTC3816 can provide high efficiency high power density and versatile power solutions for embedded computing mobile computers internet devices and navigation displays The controller is available in 38 pin ther mally enhanced eTSSOP and 5mm 7mm QFN packages The VRON pin JP15 provides enable feature To shut down the...

Страница 2: ...LTC3816EUHF 2 Table 2 IMVP 6 IMVP 6 5 VID Output Voltage Programming ...

Страница 3: ...the DVMs to the input and outputs 5 Turn on the input power supply and check for the proper output voltages Vout should be within 0 885 V to 0 915V 6 Once the proper output voltages are estab lished adjust the loads within the operating range and observe the output voltage regula tion ripple voltage and other parameters Note When measuring the output or input voltage ripple do not use the long gro...

Страница 4: ...LTC3816EUHF 4 Figure 1 Proper Measurement Equipment Setup VOUT GND COUT Figure 2 Measuring Output Voltage Ripple ...

Страница 5: ...LTC3816EUHF 5 l Figure 3 Efficiency vs load current ...

Страница 6: ...LTC3816EUHF 6 ...

Страница 7: ...LTC3816EUHF 7 ...

Страница 8: ...LTC3816EUHF 8 ...

Страница 9: ...LTC3816EUHF 9 ...

Страница 10: ...LTC3816EUHF 10 ...

Страница 11: ...LTC3816EUHF 11 ...

Страница 12: ...LTC3816EUHF 12 ...

Страница 13: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Analog Devices Inc DC1672A ...

Отзывы: