LT6551 

 

QUICK START PROCEDURE 

Demonstration  circuit  866  is  easy  to  set  up  to  evaluate 
the  performance  of  the  LT6551.  R efer  to  Figure 1  for 
proper  measurement  equipment  setup  and  follow   the 
procedure below :  

1.

 

Prior to connecting the pow er supply, preset the out-
put voltage to 5V, or to the desired level, if different. 

2.

 

W ith pow er off, connect the pow er supplies to V+ and 
G N D using banana to clip-lead cables. 

3.

 

If using a N etw ork Analyzer, perform the TH R U  trans-
mission cal w ith all cabling, adapters, impedance con-
verters, etc. in place as the reference 0dB path. 

4.

 

Energize the pow er supply.  

5.

 

Connect the  N etw ork  Analyzer  (if  used)  to  the  appro-
priate  channels  to  measure  frequency  response  and 
crosstalk as desired. 

6.

 

For  video-signal  evaluation,  connect  a  component-
video signal source to the inputs and a monitor and/or 
video analyzer to the outputs. 

 
 
 
 
 
 
 
                   

 

 COM  + 

Power Supply 

+5.00

+5.00

+5.00

+5.00 

 

 

 

Inputs 

Outputs 

 

Figure 1.

 

Proper M easurem ent Equipm ent Setup 